Device Events and Alarms
Table
Message in the Event Log | Alarm View Probable Cause | |
| Message | |
|
| |
CsEvFormat/Event00ea0018 | CsPCause/Prob00ea0018 | |
{d “%w- %d | When a system load is requested, a | |
Hub, {t} (name {m}) has reported that a | response is returned immediately and the | |
sytem load request has failed. The | load proceeds in the background. If an error | |
reason was {T slstat 1}. (event [{e}]) | is detected this trap is generated indicating | |
| the reason why in the status, as follows: | |
| (1) file not found; | |
| (2) access violation; | |
| (4) illegal TFTP operation; | |
| (5) unknown transfer ID; | |
| (7) no such user; | |
| (8) no response from the load server; | |
| (9) the download could not be started | |
| because of a lack of resources; | |
| (10) the length of a record differs from | |
| that implied by the value of the record | |
| length field; | |
| (11) the record type is not recognised; | |
| (12) record checksum error; | |
| (13) the device type in the file is incorrect; | |
| (14) the software image is not suitable for | |
| this version of the hardware; | |
| (15) the first record in the file was not a | |
| file header; | |
| (16) The byte count reported in the file | |
| trailer record differed from the | |
| number of bytes actually received. | |
| When loading a new image into the device | |
| containing the agent itself, the agent first | |
| reads the beginning of the image file to test | |
| if it is accessible and contains a valid image. | |
| If there is anything wrong, this trap is | |
| generated, no download is performed and | |
| the device continues to run uninterrupted. | |
| If this check is successful the download | |
| proper is begun. Should that fail, it is | |
| simply retried continuously until either an | |
| attempt succeeds or the device is reset. | |
|
| |
CsEvFormat/Event00ea0019 | No Probable cause message. | |
{d “%w- %d | ||
| ||
Hub, {t} (name {m}) reports the |
| |
endstation table has moved to the |
| |
modified state. (event [{e}]) |
| |
|
|