Serial I/f Application
Mrm Resilience Application
Mrm Resilience Application
This application provides access to the Mrm Resilience Table view. The model for this application is 3CommrmResApp.
Mrm Resilience View
This view contains the Mrm Resilience Table and the following:
Flush Table
Setting this menu button to Flush empties the Resilience Table. Once flushed, no resilient links are configured. You can now configure new links.
Add Entry
This button opens the Add Resilient Table Entry view. Enter the Instance of the new pair and set the Under Mod field to
StandBy Map Table
This button opens the Mrm Resilience Standby Table.
Mrm Resilience Table
A device can be configured to have a number of “resilient pairs” 802.3
For a resilient pair definition to be valid, both ports must be on the same repeater. Also, the standby port must be configured to be “disabled on boot”; that is, it must recover from a power failure in a disabled state to prevent loops in the network.
This table allows creation and deletion or resilient pairs and provides status control and information. The entries are indexed on the repeater number and slot/port location of the main port.
Repeater
Displays the repeater on which both ports in the pair are located.
9032295 E2 | Application Views |
|