Installing the SmartSwitch 9000 Module
An eight position DIP switch is located on the module card as shown in Figure
See the Cautions at the end of this table.
Table
Switch | Function | Description | |
|
| When toggled, this switch clears | |
8 | Clear | passwords stored in NVRAM, and restores the | |
Password 1 | default passwords. Once reset you can use the | ||
| |||
|
| defaults or enter new passwords. | |
|
|
| |
|
| The module uses NVRAM to store user | |
|
| entered parameters such as IP addresses, | |
|
| device name, etc. To reset these parameters to | |
7 | Clear | the factory defaults, toggle this switch. Once | |
NVRAM 2 | reset you can use the defaults or enter new | ||
| |||
|
| parameters which are stored in NVRAM when | |
|
| the module is powered down, and remain | |
|
| there until the switch is toggled again. | |
|
|
| |
|
| Toggling this switch after pulling the board | |
|
| out of the SmartSwitch 9000, clears download | |
| Force BootP | information from NVRAM and forces image | |
6 | files to be downloaded from the station | ||
Download | |||
| connected to the EPIM on the Environmental | ||
|
| ||
|
| Module configured to act as that modules’ | |
|
| BOOTP server. | |
|
|
| |
5 | Reserved | For Factory Use Only | |
|
|
| |
4 | Reserved | For Factory Use Only | |
|
|
| |
3 | Reserved | For Factory Use Only | |
|
|
| |
2 | Reserved | For Factory Use Only | |
|
|
| |
1 | Reserved | For Factory Use Only | |
|
|
|
!
CAUTION
1.Caution: Do not toggle Switch 8 unless you intend to reset the user configured passwords to their factory default settings.
2.Caution: Do not toggle Switch 7 unless you intend to reset the user parameters to the factory default settings.