If the frame’s entry is not found in the connection table, a request is sent to the system’s Virtual Network Services (VNS). The VNS checks its virtual routing tables and policy sections. If the frame’s information appears in the VNS’ virtual routing tables and the VNS’ policy section contains an entry that verifies that the frame’s source and the frame’s destination are a valid combination, then the frame is forwarded to its destination via the chassis’ SmartSwitch Bus, and a corresponding entry is written to the receiving module’s connection table. Otherwise, the frame is dropped.

1.4 SITE GUIDELINES

When choosing a location for the 7C04 Chassis, the following guidelines must be followed to ensure satisfactory network performance.

An unrestricted free surface area of 43.2 cm. (17 in.) wide,

34.8cm. (13.7 in.) deep and 16 cm. (6.3 in.) high must be available for the enclosure.

If the chassis is to be placed on a shelf, the shelf must be capable of supporting 13.5 kg. (30 pounds) of static weight.

If the chassis is to be rack mounted, care must be taken to ensure that the rack used will support the chassis and that the rack will remain stable with the chassis inserted. In order to allow proper cooling within the rack, there must be 7.6 cm. (3 in.) of clearance above the unit and 5 cm. (2 in.) of clearance on either side of the chassis in addition to the unrestricted free surface area previously detailed.

A standard three-prong power receptacle must be located within

21.13meters (7 feet) of the chassis.

The temperature of the location surrounding the chassis must be maintained between 5° and 40°C (41° to 104°F). Temperature changes of greater than 10°C (18°F) per hour must not occur.

1-5

Image 10
Contents 7C04 Workgroup SmartSWITCH Chassis User’s Guide Page FCC Notice Vcci Notice Contents Using the Smartswitch Manual SET Using this ManualChapter Introduction C04 Workgroup SmartSwitch Chassis Chassis Overview1 7X00 SmartSwitch Controller Module SmartSwitch interface modulesSecureFast Packet Switch Traditional SwitchOperations Site Guidelines Related Manuals Getting HelpChapter Installation Unpacking the 7C04 ChassisInstalling the 7C04 Chassis in AN Equipment Rack Attaching Mounting BracketsAttaching the Right Mounting Bracket to the 7C04 Chassis Mounting the 7C04 Chassis A 7C04 Chassis mounted in an equipment rackUnpacking the Power Supply Module 7C04 Chassis Power Supply ModuleInstalling the Power Supply Module Notch Powering up the Power Supply Module Removing the Power Supply Module Power Supply ModuleLEDsWork Group SmartSwitch Chapter TroubleshootingLED Color Indicates Action Overload LED EMI Chapter Technical SpecificationsSafety ImmunityDimensions ServicePower WeightEnvironmental