Introduction

1.3.3 Operations

Data entering through a front panel of a SmartSwitch interface module in the 7C04 Chassis is converted by the module’s hardware into a common “canonical” format. Canonical frames are forwarded along the chassis’ SmartSwitch Bus to the 7X00 Module in slot one. The configuration of the 7X00 Module (either traditional switch or SecureFast Packet Switch) determines the manner in which frames are filtered or forwarded.

Traditional Switch

When operating as a traditional switch (a store-and-forward switch using the 802.1d Spanning Tree protocol), the 7X00 Module’s SmartSwitch Core searches for the frame’s destination address in the module’s connection table.

If the frame’s destination address is found in the connection table, the frame is forwarded to that specific destination via the chassis’ SmartSwitch Bus.

If the frame’s destination address is not found in the connection table, the frame is flooded to all of the SmartSwitch interface modules in the chassis via the chassis’ SmartSwitch Bus. The frame’s destination address is added to the module’s connection table.

SecureFast Packet Switch

When operating as a SecureFast Packet Switch, the 7X00 Module’s SmartSwitch Core searches for the frame’s destination address- source address (DA-SA) pair and receive port in the module’s connection table.

If the frame’s entry is found in the connection table, the frame is forwarded to a specific destination via the chassis’ SmartSwitch Bus.

1-4

Image 9
Contents 7C04 Workgroup SmartSWITCH Chassis User’s Guide Page FCC Notice Vcci Notice Contents Using this Manual Using the Smartswitch Manual SETChapter Introduction Chassis Overview C04 Workgroup SmartSwitch ChassisSmartSwitch interface modules 1 7X00 SmartSwitch Controller ModuleTraditional Switch SecureFast Packet SwitchOperations Site Guidelines Getting Help Related ManualsUnpacking the 7C04 Chassis Chapter InstallationAttaching Mounting Brackets Installing the 7C04 Chassis in AN Equipment RackAttaching the Right Mounting Bracket to the 7C04 Chassis A 7C04 Chassis mounted in an equipment rack Mounting the 7C04 Chassis7C04 Chassis Power Supply Module Unpacking the Power Supply ModuleInstalling the Power Supply Module Notch Powering up the Power Supply Module Power Supply Module Removing the Power Supply ModuleChapter Troubleshooting LEDsWork Group SmartSwitchLED Color Indicates Action Overload LED Safety Chapter Technical SpecificationsEMI ImmunityPower ServiceDimensions WeightEnvironmental