EMC QLogic manual Configuring Nvram for Stratus ftServers

Page 21

Configuring NVRAM for Stratus ftServers

Installing and Configuring the HBA Driver

If you have not received QLogic HBAs with the EMC configurations pre-loaded, you may have to perform the following procedure. If your HBAs have been pre-configured, proceed to Installing the HBA Driver on page 2-14.

During POST, Stratus ftServers present only one HBA for configuration in a multiple-HBA system. This is the way the ftServer manages HBA failover. In order to successfully configure multiple HBAs, each HBA must be part of an enabled Core PCI chassis at some point. The following procedure explains how this can be done for each chassis.

On Stratus ftServer 5200 systems, the HBA must be in a Core Chassis. Cards in an Expansion Chassis must be moved to a Core Chassis to be available for configuration.

1.To set the first HBA, follow these procedures:

Updating Firmware/BIOS and Applying NVRAM Settings on page 2-10

Manually Setting the HBA Data Rate on page 2-12

Setting the Topology for QLA22xx/23xx and Windows on page 2-13

Ignore any steps that pertain to multiple adapters.

Note the Core PCI Chassis that is powered up while changing the settings. After completing the changes, power down the system and prepare to configure the alternate chassis.

2.Noting the PCI Chassis that was powered up in the previous step:

For Stratus ftServer 3200 systems, loosen the Phillips-head screw on the top right of the chassis, effectively removing power from that chassis.

For Stratus ftServer 5200 systems, leave the chassis powered down.

3.Power up the system using the alternate PCI Chassis and set the second HBA by following these procedures:

Updating Firmware/BIOS and Applying NVRAM Settings on page 2-10

Manually Setting the HBA Data Rate on page 2-12

Setting the Topology for QLA22xx/23xx and Windows on page 2-13

EMC HBA Settings

2-9

 

 

2

Image 21
Contents REV A07 Trademark Information Copyright 2001-2005 EMC Corporation. All rights reservedContents Chapter Configuring an EMC Boot Device Chapter Installing and Configuring the QLogic QLA4010 iSCSI Appendix B TroubleshootingAppendix a Third-Party Software Problem Index EMC uses the following conventions for notes, cautions, Damage to the system or equipment. The caution may apply toHardware or software Related Documentation Typographical Conventions PalatinoBold Introduction Understanding Persistent Binding in a Fabric Environment Understanding Persistent Binding in a Fabric Environment HBA Installing Configuring the HBA Driver Downloading QLogic Drivers Firmware Verifying Documentation IntroductionInstalling an HBA Check for an Updated HBA Driver Move the jumpers, onto pins 1-2 if not already there Reconfigure the HBA JumperSet the HBA FC-AL Loop ID Installing an HBA Pre-Configured EMC HBA SettingsSettings Settings menusConfiguring Nvram for Stratus ftServers Fibre-Down Servers Firmware/BIOSWith Embedded QLogic HBAsUpdating While Running Windows Press the Down Arrow until you select Data Rate then press EMC HBA Settings Driver Revision History Where to Find the Driver Installing the HBA DriverExtended Error Logging by QLogic Drivers Windows 2003 STORPort UpdatesInstallation Procedure for Windows NT Hosts Select have DiskAdministrative Tools, Computer Management Installing the HBA Driver Double-click the Scsi & RAID Controllers icon Installing and Configuring the HBA Driver Upgrading to Windows 2003 from Windows 2000 or Windows NT Replacing an HBA Masking Enabled EMC SymmetrixArrays with Device Powermt restore powermt display Installing and Configuring the HBA Driver Configuring an EMC Boot Device Risks of Booting from the Storage Array Boot-from-SAN Configuration RestrictionsHow to Determine I/O Latency and Load on the Boot LUN Boot-from-SAN with Mscs Boot Crashdump Save to Disk BehaviorConfiguring the Boot Bios Configuring a Symmetrix Boot DeviceFrom the Host Adapter Settings menu, select Host Adapter From the Configuration Settings menu, select Host AdapterSelect Current Boot Node Name and press Enter Configuration Settings menuInstalling the Windows OS onto the Boot Device Installing EFI boot code onto the HBA Unload 5D Configuring an EMC Boot Device Configurable Components Drv5DCtrl60Langeng Configuring an EMC Boot Device Configuring a Symmetrix Boot Device Configuring a CLARiiON Boot Device ProcedureFlowchart Configuring a CLARiiON Boot Device Configurations, Revisions Hardware Software Requirements RequirementsTopologies Refer to Downloading QLogic Drivers and Firmware on Preparing the Storage SystemSetting Up the HBA Bios Preparing the Fabric Configuring an EMC Boot Device What Next? Node NamePreparing the Server Boot Bios Configuring the HBAConfiguring an EMC Boot Device When the QLogic Bios banner shown in appears, press Windows Licensing Agreement appears Configuring a CLARiiON Boot Device Verifying HBA Driver and Digital Signature Installation Assigning a Permanent Boot Drive Letter for Windows NT Installing Multipath and Failover SoftwareWhat Next? From here Installing Additional Navisphere Host Agent Software Storagegroupname y/n? Configuring an EMC Boot Device On the Computer Management window, click Disk Management Trespassing the Boot LUN Using atftrespassStarting a Fresh Installation Boot Time and LUN AvailabilityBoot Time and LUN Availability EMC Symmetrix EMC CLARiiON Replacing a Boot HBAExplanations of Entries How a Server Responds to Failure in the Boot LUN PathNtosknl Bsod Known IssuesHBA TOE Windows 2003 STORPort Updates Next dialog, click ReInstall Driver, and then, click Next Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Configuring iSNS settings for QLA4010 Configuring iSNS settings for QLA4010 Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Configuring iSNS settings for QLA4010 Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Configuring iSNS settings for QLA4010 Installing Boot Bios on the QLA4010 iSCSI HBA from DOS Select iSCSI Boot Settings Select Configuration Settings from the menuSelect iSCSI Boot Settings, and press Enter Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Third-Party Software QLogic SANSurfer SANBlade Manager SANSurfer versions include Initial Release SANSurfer Version HistoryVeritas Volume Manager Veritas Volume Manager 3.x for WindowsVeritas Foundation Suite Veritas Volume Manager 3.1 and Veritas DMPThird-Party Software Troubleshooting Problems and Solutions ProblemSolution Later already contain this correction Flasutil Index Nvram

QLogic specifications

EMC QLogic is a leading provider of advanced networking solutions, primarily known for its high-performance storage area network (SAN) technologies. It specializes in Fibre Channel and Ethernet networking products, offering robust solutions that are essential for modern data center environments.

One of the key features of EMC QLogic is its exceptional performance in high-speed data transfer. QLogic's Fibre Channel products, such as switches and host bus adapters (HBAs), support speeds of up to 32 Gbps, ensuring ultra-fast communication between storage devices and servers. This high throughput is crucial for applications demanding high IOPS (Input/Output Operations Per Second), particularly in virtualized environments and databases.

Another prominent aspect of EMC QLogic's technology is its support for advanced features like Data Center Bridging (DCB). DCB enables the convergence of storage and traditional Ethernet traffic on a single network, streamlining data center management and reducing costs. By allowing both storage and data networking to coexist on the same infrastructure, EMC QLogic enhances efficiency and simplifies network architecture.

Scalability is another characteristic that sets EMC QLogic apart. The architecture is designed to support a wide range of deployment sizes, from small businesses to large enterprise data centers. This scalability ensures that organizations can grow their IT infrastructure without needing to overhaul their existing deployment.

EMC QLogic also places a strong emphasis on reliability and security. Their products are built with redundancy and failover mechanisms, which minimize downtime and ensure continuous operation even in the event of hardware failure. Additionally, security features such as encryption and access controls are integrated to protect sensitive data as it travels across the network.

Management and monitoring capabilities are also integral to EMC QLogic's offerings. The company provides advanced software tools for managing network resources, allowing administrators to monitor performance, diagnose issues, and optimize configurations efficiently. This helps organizations maintain peak performance and reduces operational complexity.

In summary, EMC QLogic combines high-speed performance, advanced features, and robust reliability in its networking solutions. With a focus on scalability and security, it provides organizations with the tools necessary to build and manage efficient, modern data centers that can adapt to evolving technological demands. Its commitment to innovation positions EMC QLogic as a trusted partner in the storage networking landscape.