EMC QLogic manual Configuring an EMC Boot Device

Page 60

3

Configuring an EMC Boot Device

Different HBA models may display different banners. Be sure to select

CTRL-Qfor the HBA you wish to configure.

QLogic Corporation

QLA2300 PCI Fibre Channel ROM BIOS Version 1.17

Copyright © Qlogic Corporation 1993-1999 All rights reserved

Press <CTRL - Q> for Fast!UTIL

www.qlogic.com

2.After Fast!UTIL loads, the display depends on whether there are multiple QLogic HBAs installed:

If there is only one QLogic HBA, the Fast!UTIL Options menu appears.

If there are multiple QLogic HBAs, a list of addresses occupies by those HBAs appears. Use the arrow keys to select the desired HBA; then press ENTER. The Fast!UTIL Options menu appears.

3.Select Configuration Settings from the menu.

4.Select Selectable Boot Settings from the Configuration Settings menu.

Select the first Boot Port Name entry, and in the Device window scroll to select the CLARiiON port WWN from which you want to boot.

Depending on the array model, the HBA may not yet detect any LUNs, or it may detect a LUNZ labeled disk. This is normal behavior.

Leave the server here so the HBA will remain active while you configure the storage array groups.

5.Using EMC ControlCenter Navisphere Management software, you must add the HBA to the storage group you created earlier. Depending on the array model, you may have to first manually register the HBA connection. If you will later install PowerPath or ATF, be sure to select the corresponding parameters during the registration procedure. Refer to your EMC ControlCenter Navisphere Management software, ATF, or PowerPath documentation for detailed instructions.

6.Press ESC until you exit the Fast!UTIL Options menu. You do not need to save any changes if prompted.

7.Reboot the server.

3-24

EMC Fibre Channel with QLogic HBAs in the Windows Environment

 

 

Image 60
Contents REV A07 Copyright 2001-2005 EMC Corporation. All rights reserved Trademark InformationContents Chapter Configuring an EMC Boot Device Chapter Installing and Configuring the QLogic QLA4010 iSCSI Appendix B TroubleshootingAppendix a Third-Party Software Problem Index EMC uses the following conventions for notes, cautions, Damage to the system or equipment. The caution may apply toHardware or software Related Documentation Typographical Conventions PalatinoBold Introduction Understanding Persistent Binding in a Fabric Environment Understanding Persistent Binding in a Fabric Environment HBA Installing Configuring the HBA Driver Introduction Downloading QLogic Drivers Firmware Verifying DocumentationInstalling an HBA Check for an Updated HBA Driver Reconfigure the HBA Jumper Move the jumpers, onto pins 1-2 if not already thereSet the HBA FC-AL Loop ID Installing an HBA EMC HBA Settings Pre-ConfiguredSettings Settings menusConfiguring Nvram for Stratus ftServers Firmware/BIOS Fibre-Down ServersWith Embedded QLogic HBAsUpdating While Running Windows Press the Down Arrow until you select Data Rate then press EMC HBA Settings Installing the HBA Driver Driver Revision History Where to Find the DriverWindows 2003 STORPort Updates Extended Error Logging by QLogic DriversInstallation Procedure for Windows NT Hosts Select have DiskAdministrative Tools, Computer Management Installing the HBA Driver Double-click the Scsi & RAID Controllers icon Installing and Configuring the HBA Driver Upgrading to Windows 2003 from Windows 2000 or Windows NT Replacing an HBA Masking Enabled EMC SymmetrixArrays with Device Powermt restore powermt display Installing and Configuring the HBA Driver Configuring an EMC Boot Device Boot-from-SAN Configuration Restrictions Risks of Booting from the Storage ArrayHow to Determine I/O Latency and Load on the Boot LUN Boot Crashdump Save to Disk Behavior Boot-from-SAN with MscsConfiguring a Symmetrix Boot Device Configuring the Boot BiosFrom the Configuration Settings menu, select Host Adapter From the Host Adapter Settings menu, select Host AdapterSelect Current Boot Node Name and press Enter Configuration Settings menuInstalling the Windows OS onto the Boot Device Installing EFI boot code onto the HBA Unload 5D Configuring an EMC Boot Device Configurable Components Drv5DCtrl60Langeng Configuring an EMC Boot Device Configuring a Symmetrix Boot Device Configuring a CLARiiON Boot Device ProcedureFlowchart Configuring a CLARiiON Boot Device Configurations, Revisions Hardware Software Requirements RequirementsTopologies Preparing the Storage System Refer to Downloading QLogic Drivers and Firmware onSetting Up the HBA Bios Preparing the Fabric Configuring an EMC Boot Device Node Name What Next?Preparing the Server Configuring the HBA Boot BiosConfiguring an EMC Boot Device When the QLogic Bios banner shown in appears, press Windows Licensing Agreement appears Configuring a CLARiiON Boot Device Verifying HBA Driver and Digital Signature Installation Assigning a Permanent Boot Drive Letter for Windows NT Installing Multipath and Failover SoftwareWhat Next? From here Installing Additional Navisphere Host Agent Software Storagegroupname y/n? Configuring an EMC Boot Device Trespassing the Boot LUN Using atftrespass On the Computer Management window, click Disk ManagementBoot Time and LUN Availability Starting a Fresh InstallationBoot Time and LUN Availability Replacing a Boot HBA EMC Symmetrix EMC CLARiiONHow a Server Responds to Failure in the Boot LUN Path Explanations of EntriesKnown Issues Ntosknl BsodHBA TOE Windows 2003 STORPort Updates Next dialog, click ReInstall Driver, and then, click Next Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Configuring iSNS settings for QLA4010 Configuring iSNS settings for QLA4010 Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Configuring iSNS settings for QLA4010 Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Configuring iSNS settings for QLA4010 Installing Boot Bios on the QLA4010 iSCSI HBA from DOS Select Configuration Settings from the menu Select iSCSI Boot SettingsSelect iSCSI Boot Settings, and press Enter Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Installing and Configuring the QLogic QLA4010 iSCSI HBA TOE Third-Party Software QLogic SANSurfer SANBlade Manager SANSurfer Version History SANSurfer versions include Initial ReleaseVeritas Volume Manager 3.x for Windows Veritas Volume ManagerVeritas Volume Manager 3.1 and Veritas DMP Veritas Foundation SuiteThird-Party Software Troubleshooting Problems and Solutions ProblemSolution Later already contain this correction Flasutil Index Nvram

QLogic specifications

EMC QLogic is a leading provider of advanced networking solutions, primarily known for its high-performance storage area network (SAN) technologies. It specializes in Fibre Channel and Ethernet networking products, offering robust solutions that are essential for modern data center environments.

One of the key features of EMC QLogic is its exceptional performance in high-speed data transfer. QLogic's Fibre Channel products, such as switches and host bus adapters (HBAs), support speeds of up to 32 Gbps, ensuring ultra-fast communication between storage devices and servers. This high throughput is crucial for applications demanding high IOPS (Input/Output Operations Per Second), particularly in virtualized environments and databases.

Another prominent aspect of EMC QLogic's technology is its support for advanced features like Data Center Bridging (DCB). DCB enables the convergence of storage and traditional Ethernet traffic on a single network, streamlining data center management and reducing costs. By allowing both storage and data networking to coexist on the same infrastructure, EMC QLogic enhances efficiency and simplifies network architecture.

Scalability is another characteristic that sets EMC QLogic apart. The architecture is designed to support a wide range of deployment sizes, from small businesses to large enterprise data centers. This scalability ensures that organizations can grow their IT infrastructure without needing to overhaul their existing deployment.

EMC QLogic also places a strong emphasis on reliability and security. Their products are built with redundancy and failover mechanisms, which minimize downtime and ensure continuous operation even in the event of hardware failure. Additionally, security features such as encryption and access controls are integrated to protect sensitive data as it travels across the network.

Management and monitoring capabilities are also integral to EMC QLogic's offerings. The company provides advanced software tools for managing network resources, allowing administrators to monitor performance, diagnose issues, and optimize configurations efficiently. This helps organizations maintain peak performance and reduces operational complexity.

In summary, EMC QLogic combines high-speed performance, advanced features, and robust reliability in its networking solutions. With a focus on scalability and security, it provides organizations with the tools necessary to build and manage efficient, modern data centers that can adapt to evolving technological demands. Its commitment to innovation positions EMC QLogic as a trusted partner in the storage networking landscape.