Extron electronic MTP 15HD RSA manual Maximum Transmission Distances for Analog Signals at 60 Hz

Page 11

Maximum Transmitter to Receiver Distance — Analog Signals at 60 Hz

Video Format

With Pre-Peak Off. With Pre-Peak On.

Feet (Meters)

Feet (Meters)

Max. Distance

Max. Distance

(High Quality).

(Variable Quality).

Feet (Meters)

Feet (Meters)

 

 

 

Composite,

 

 

 

 

 

 

S-video,

 

 

800 (245)

1000 (300)

 

 

Component Video

 

 

 

 

 

 

640 x 480

<300 (90)

>350 (105)

700 (215)

750 (230)

 

 

 

 

 

 

 

 

 

800 x 600

<300 (90)

>350 (105)

550 (170)

650 (200)

 

 

 

 

 

 

 

 

 

1024 x 768*

<300 (90)

>350 (105)

500 (150)

600 (185)

 

 

 

 

 

 

 

 

 

1280 x 960

<300 (90)

>350 (105)

400 (120)

500 (150)

 

 

 

 

 

 

 

 

 

1280 x 1024*

<250 (75)

>300 (90)

350 (105)

450 (135)

 

 

 

 

 

 

 

 

 

1360 x 765

<250 (75)

>300 (90)

400 (120)

500 (150)

 

 

 

 

 

 

 

 

 

1365 x 768

<250 (75)

>300 (90)

400 (120)

450 (135)

 

 

 

 

 

 

 

 

 

1366 x 768

<250 (75)

>300 (90)

400 (120)

450 (135)

 

 

 

 

 

 

 

 

 

1400 x 1050

<250 (75)

>300 (90)

350 (105)

400 (120)

 

 

 

 

 

 

 

 

 

1440 x 900

<250 (75)

>300 (90)

350 (105)

400 (120)

 

 

 

 

 

 

 

 

 

1600 x 1200*

<250 (75)

>300 (90)

300 (90)

450 (135)

 

 

 

 

 

 

 

 

 

1920 x 1200

<250 (75)

>300 (90)

300 (90)

400 (120)

 

 

 

 

 

 

 

 

 

2048 x 1080

<250 (75)

>300 (90)

300 (90)

400 (120)

 

 

 

 

 

 

 

 

 

HDTV 720p

<250 (75)

>300 (90)

400 (120)

500 (150)

 

 

 

 

 

 

 

 

 

HDTV 1080i

<250 (75)

>300 (90)

300 (90)

400 (120)

 

 

 

 

 

 

 

 

 

HDTV 1080p

<250 (75)

>300 (90)

300 (90)

400 (120)

 

 

 

 

 

 

 

 

*same spec at 75 Hz

Figure 6. Maximum Transmission Distances for Analog Signals at 60 Hz

fRS-232 connector (3-pole captive screw - MTP T 15HD RSA only) — Connect to this for bi- or unidirectional RS-232 communication. The RS-232 function is only available by setting the on-the-board DIP switch from audio to RS-232 communication. The default is audio.

See page 8 for setting the DIP switch.

gSkew, Peaking and Level LEDs (MTP R 15HD RSA SEQ only) — These three LEDs (red, green, and blue) are used to indicate the misaligned colors when adjusting the Skew Equalization settings. They are also used for identifying Peaking and Level modes when adjusting for signal loss or optimizing the image for various cable lengths. The LEDs are labelled: R =Red, G/L = Green/Level, B/P = Blue/Peaking

NOTES: Skew is the color misalignment present in twisted pair A/V systems using

Category 5, 5e, or 6 cable in which the red, green, and blue video signals

arrive at the display at different times.

Level alters the video output voltage to affect the brightness of the

displayed image.

Peaking affects the sharpness of a picture.

hSelect Button (MTP R 15HD RSA SEQ only) — This recessed button selects between, Skew Equalization, Level, and Peaking when adjustments are needed.

iRotary Adjust Knob (MTP R 15HD RSA SEQ only) — Within any function, rotate this Adjust knob to make the appropriate changes to the skew delay, level, or peaking.

PowerCage MTP T 15HD RSA and PowerCage MTP R 15HD RSA SEQ • Installation and Operation

7

Image 11
Contents MTP Twisted Pair Transmitter and Receiver Modular Boards PowerCage MTP 15HD RSA SeriesSafety Instructions English Copyright Contents About this Guide About the PowerCage MTP 15HD RSA Transmitters and ReceiversIntroduction Features Page Installing the Boards into the PowerCage Enclosure Installation OperationAudio connector 5-pole captive screw Board Connections, LEDs, and Rear Panel FeaturesSee distance table on Maximum Transmission Distances for Analog Signals at 60 Hz PowerCage Front Panel PowerCage Front Panel Port, Control, and IndicatorsPosition Resolution Board Setup and OperationChanging the MTP T 15HD RSA Board Settings Switch Position Switch #1 Setting Switch #2 SettingButton Function LED Color Skew, Level, and Peaking AdjustmentsFor Skew adjustment Operation For Level AdjustmentFor Peaking Adjustment Resetting Skew Delay, Level and PeakingReference Information SpecificationsVideo input PowerCage MTP T 15HD RSA Video output PowerCage MTP R 15HD RSA SEQControl/Remote Sync PowerCage MTP T 15HD RSA, PowerCage MTP R 15HD RSA SEQAudio input PowerCage MTP T 15HD RSA Audio output PowerCage MTP R 15HD RSA SEQMtbf GeneralIncluded Parts PowerCage MTP 15HD RSA Part NumbersCables and Connectors Part NumbersEurope USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle East