General

Recommended cable type

Extron Enhanced Skew-FreeA/V UTP, CAT 5/5e/6 (shielded or unshielded)

Power consumption*

1 or 2* (positive-negative), 100 VAC to 240 VAC, 50-60 Hz; internal, hot-swappable

 

*A redundant power supply is optional.

Each MTP board at 115 VAC, 60 Hz

 

MTP T 15HD RSA: 4.30 watts

 

MTP R 15HD RSA SEQ: 8.38 watts

Power input requirements (I/O boards)

 

12 VDC, 1.0 A, supplied by the PowerCage enclosure

Temperature/humidity

Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing

 

Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing

Cooling

Boards: convection, within the PowerCage enclosure

Enclosure type

Metal

Enclosure dimensions

 

PowerCage MTP R 15HD RSA SEQ

 

Fits a double slot opening in a PowerCage enclosure.

PowerCage MTP T 15HD RSA . Fits a single slot opening in a PowerCage enclosure.

Product weight

 

PowerCage MTP R 15HD RSA SEQ

 

1.0 lbs (0.5 kg)

PowerCage MTP T 15HD RSA ..

0.8 lbs (0.4 kg)

Shipping weight

 

PowerCage boards

2 lbs (1 kg) each

Vibration

ISTA 1A in carton (International Safe Transit Association)

Regulatory compliance

 

Safety

CE, c-UL, UL

EMI/EMC

CE, C-tick, FCC Class A, ICES, VCCI

MTBF

30,000 hours

Warranty

3 years parts and labor

NOTES: All nominal levels are at ±10%.

Specifications are subject to change without notice.

PowerCage MTP T 15HD RSA and PowerCage MTP R 15HD RSA SEQ • Reference Information

14

Image 18
Contents PowerCage MTP 15HD RSA Series MTP Twisted Pair Transmitter and Receiver Modular BoardsSafety Instructions English Copyright Contents About the PowerCage MTP 15HD RSA Transmitters and Receivers IntroductionAbout this Guide Features Page Installation Operation Installing the Boards into the PowerCage EnclosureBoard Connections, LEDs, and Rear Panel Features Audio connector 5-pole captive screwSee distance table on Maximum Transmission Distances for Analog Signals at 60 Hz PowerCage Front Panel Port, Control, and Indicators PowerCage Front PanelSwitch Position Switch #1 Setting Switch #2 Setting Board Setup and OperationChanging the MTP T 15HD RSA Board Settings Position ResolutionSkew, Level, and Peaking Adjustments For Skew adjustmentButton Function LED Color Resetting Skew Delay, Level and Peaking For Level AdjustmentFor Peaking Adjustment OperationVideo output PowerCage MTP R 15HD RSA SEQ SpecificationsVideo input PowerCage MTP T 15HD RSA Reference InformationAudio output PowerCage MTP R 15HD RSA SEQ Sync PowerCage MTP T 15HD RSA, PowerCage MTP R 15HD RSA SEQAudio input PowerCage MTP T 15HD RSA Control/RemoteGeneral MtbfPart Numbers PowerCage MTP 15HD RSA Part NumbersCables and Connectors Included PartsAsia Middle East USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Europe