Installation and
Operation
This section describes the installation and operation of the PowerCage MTP T 15HD RSA and MTP R 15HD RSA SEQ, including:
•Installing the Boards into the PowerCage Enclosure
•Board Connections, LEDs, and Rear Panel Features
•PowerCage Front Panel Port, Control, and Indicators
•Board Setup and Operation
Installing the Boards into the PowerCage Enclosure
Up to 16 single slot or 8 dual slot input/output boards can be inserted into the PowerCage enclosure. The PowerCage MTP T 15HD RSA transmitters are single slot boards, and PowerCage MTP R 15HD RSA SEQ receivers are dual slot boards.
NOTES: The boards are
CAUTION: Use ESD precautions when installing a board to avoid damaging the board. Keep the board in the
1.Where applicable, remove as many blank plates or previously installed boards from the rear of the PowerCage as necessary for the number of new boards to be installed.
2.Hold the board with the signal connectors towards you and the LED at the top, and align the top and bottom grooves of the board with the slide posts in the selected enclosure slot. See the example in figure 1.
16 Available Single Board Slots or
8 Double Board Slots
Power Supply
| Tx Rx |
| 1 2 |
FIBER |
| TxRx | |
TxRx | REMOTE | ||
R |
| ||
OVER | AUDIO L |
|
OUTPUT | RGB |
INPUT |
|
Tx Rx |
|
C |
|
Align board and | |
slide into slot. | |
Tx Rx | 1 2 |
FIBER |
| TxRx | |
TxRx | REMOTE | ||
R |
| ||
OVER | AUDIO L |
| |
Screws |
| OUTPUT | RGB |
(2 per board) |
|
|
|
Figure 1. Inserting Boards into the PowerCage Enclosure
PowerCage MTP T 15HD RSA and PowerCage MTP R 15HD RSA SEQ • Installation and Operation | 4 |