The scaler’s RS-232 connector can be connected to the serial port output of a host device such as a computer or control system. This connection makes software control of the scaler possible. Figure 10 shows a scaler RS-232 connection to a host serial port connector.

OUTPUTSREMOTE

RGB

RGB

HVS

RS-232

Control Cable

Computer Control

DVS 150

Figure 10 — Scaler RS-232 to host connection

The RS-232 connector on the scaler is a 9-pin D female connector with the following pin assignments:

Pin Description

1Input 1 select*

2Transmit data

3Receive data

4Input 2 select*

5Signal ground

6Input 3 select*

7Input 4 select*

8Not used

9Not used

*Used for remote contact closure control

The protocol is 9600 baud, 8-bit, 1 stop bit, no parity, and no flow control.

The scaler accepts SIS™ (Simple Instruction Set™) commands through the RS-232 port. SIS commands consist of one or more characters per command field. They do not require any special characters to begin or end the command character sequence. Each scaler response to an SIS command ends with a carriage return and a line feed (CR/LF = ), which signals the end of the response character string. (A string is one or more characters.)

RS-232 Programmer’s Guide

DVS initiated messages

When a local event occurs, such as a front panel operation, the scaler responds by sending a message to the host. The DVS-initiated messages are listed below (underlined).

(C) Copyright 1999, Extron Electronics, DVS 150, Vx.xx

The copyright message is initiated by the scaler when it is first powered on. Vx.xx is the firmware version number.

Reconfig

The Reconfig message is initiated by the scaler when a new input is selected or when any image adjustment is made.

The scaler does not expect a response from the host, but, for example, the host program might request a new status.

4-2 DVS 150 Serial Communication

Image 24 Contents
DVS Digital Video ScalerPrecautions Safety Instructions EnglishConsignes de Sécurité Français Sicherheitsanleitungen DeutschInstallation Quick Start DVSConfiguring the Scaler Table of Contents Table of Contents, cont’d One IntroductionFeatures IntroductionAbout the Scaler DVS 150 IntroductionDVS 150 Introduction Introduction, cont’d Installation TwoInstallation Rear Panel FeaturesInstallation DVS 150 InstallationInstalling the rubber feet Mounting the scalerInstallation, cont’d CablingFront Panel Features DVS 150 front panelConfiguring the Scaler Configuration settingsDVS 150 Installation Installation, cont’d Three Operation Default screens Adjusting an image Operation Front Panel OperationMinimum, maximum, and default value screens Choosing the output rateFreeze mode Executive modeChannel reset System resetFour Serial CommunicationSerial Communication RS-232 Programmer’s GuideDVS initiated messages DVS 150 Serial CommunicationDVS error response Using the command/response tableRemote Contact Closure Operation Command/response table Serial Communication, cont’dInstalling the software Control Software for WindowsUsing the software Signal Enhancement Products Control ProgramTroubleshooting FiveTroubleshooting Operating ProblemsDVS 150 Troubleshooting DVS 150 Troubleshooting Troubleshooting, cont’d AAppendix Reference InformationSpecifications Reference InformationDVS 150 Reference Information BNC cables Assorted connectors BNC Connectors Pre-cut cablesBNC-4 HR Cable BNC-5 HR CableFCC Class B Notice Extron ELECTRONICS, Asia