Extron electronic DVS 150 manual Mounting the scaler, Installing the rubber feet

Page 13

6

7

Use the LCD menu screens to configure the scaler. See “Configuring the Scaler” on page 2-6.

The image from the input device should appear on the output device. If it does not, double check steps 3 and 4 and make adjustments as needed, and then see “Operating Problems” on page 5-2.

Mounting the scaler

Each DVS 150 ships with four uninstalled rubber feet. If you are going to rack mount the unit, do so before cabling it, and do not install the rubber feet. If you are not rack mounting the scaler, skip to “Installing the rubber feet” below.

The DVS 150 can be rack mounted using one side of an optional 19” 1U Universal Rack Shelf (Extron part # 60-190-01).

To rack mount the scaler, do the following:

1.If rubber feet were previously installed on the bottom of the case, remove them.

2.Mount the scaler on the rack shelf as shown in figure 2. Use two

4-40 x 1/8” screws in opposite (diagonal) corners to secure the case to the shelf.

Faulse Front panel uses 2 front holes

INPUT

1 2 3

4 COLOR TINT

BRIT

 

CONTRAST

H

 

SHIFT

VSHIFT

RATE

 

 

 

DIGITAL

DVS

100

 

VIDEO

 

 

 

SCALER

(2) 4-40 x 1/8" Screws

Use 2 mounting holes on opposite corners

Figure 2 — Mounting the scaler

Installing the rubber feet

The scaler ships with four uninstalled rubber feet. Install the rubber feet only if you are not rack mounting the scaler. To install the rubber feet, do the following:

1.Turn the scaler upside down and place it on a flat surface.

2.Remove the protective backing from a rubber foot.

DVS 150 Installation

2-3

Image 13
Contents Digital Video Scaler DVSSafety Instructions English PrecautionsConsignes de Sécurité Français Sicherheitsanleitungen DeutschQuick Start DVS InstallationConfiguring the Scaler Table of Contents Table of Contents, cont’d Introduction OneIntroduction FeaturesAbout the Scaler DVS 150 IntroductionDVS 150 Introduction Introduction, cont’d Two InstallationRear Panel Features InstallationInstallation DVS 150 InstallationMounting the scaler Installing the rubber feetCabling Installation, cont’dDVS 150 front panel Front Panel FeaturesConfiguration settings Configuring the ScalerDVS 150 Installation Installation, cont’d Operation ThreeAdjusting an image Default screensOperation Front Panel OperationChoosing the output rate Minimum, maximum, and default value screensExecutive mode Freeze modeChannel reset System resetSerial Communication FourRS-232 Programmer’s Guide Serial CommunicationDVS initiated messages DVS 150 Serial CommunicationUsing the command/response table DVS error responseRemote Contact Closure Operation Serial Communication, cont’d Command/response tableControl Software for Windows Installing the softwareSignal Enhancement Products Control Program Using the softwareFive TroubleshootingOperating Problems TroubleshootingDVS 150 Troubleshooting DVS 150 Troubleshooting Troubleshooting, cont’d Reference Information AAppendixReference Information SpecificationsDVS 150 Reference Information BNC cables Pre-cut cables Assorted connectors BNC ConnectorsBNC-4 HR Cable BNC-5 HR CableFCC Class B Notice Extron ELECTRONICS, Asia