Extron electronic SFI244 Series, IPL T SF24 user manual IR Learning SFI244 only

Page 25

Communication and Control, cont’d

2.Click the Browse button to locate the file you want to upload.

3.Click the Upload File button to upload the file.

The file will be added to the list of files under the Files column. After ten files have been loaded, additional file management pages will appear in the page navigation area (on the right side of the screen).

To delete unwanted files:

1.Select the File Management tab and the File Management screen (figure 4-17) is displayed.

2.Find the file you wish to delete under the Files list.

3.Click the Delete button of the file to be deleted. If you wish to delete additional files, wait for the screen to refresh before clicking the delete button of the next file.

If you wish to delete all files, click the Delete All button. The file count will revert to 0 and all subsequent pages will be deleted.

IR Learning (SFI244 only)

The IPL T SFI244 IR can “learn” commands from a third-party remote control device in order to control devices such as VCRs, audio tape players, or DVD players. IR learning can be performed in conjunction with the Global Viewer to assist in controlling commonly used functions.

During IR learning, the user must hold the device remote between 2” and 12” away from the IR pick up device. See figure 4-18 for an example.

 

T SFI2

44

IPL

 

15 deg. (typ)

2-12"

Figure 4-18 — IR remote distance

Creating a driver with the IR Learner software

In order to use your third-party remote device with the

IPL T SFI244, the functions of your third–party driver must be “learned” by the IPL T unit. In other words, you must create a driver for your remote control device. You have the option of creating a new, custom driver or manipulating an existing driver. Both can be accessed or created through the IR Learner software.

To create a driver for your remote control device, do the following:

1.Launch the IR Learner software application. The application window will appear; there will be no open drivers.

2.Create a new or empty driver by selecting File->New. A driver document is created, and its Header tab is selected.

Figure 4-19 — Creating a new driver

3.Edit the Header fields (figure 4-19), the most important of which is Type. The driver will be populated with a default set of commands according to the selected device type. A device type of “Other” creates an empty driver with no functions.

4.Add functions by pressing the Add button in the toolbar.

User definable functions may be added to the driver. The names and ordering of user definable functions may be changed at any time by double clicking on the function to be renamed. The names and ordering of any default functions can not be altered.

4-14 IPL T SF24 and IPL T SFI244 • Communication and Control

IPL T SF24 and IPL T SFI244 • Communication and Control

4-15

Image 25
Contents USA IP Link ToolsExtron’s Warranty PrecautionsFCC Class a Notice Under Desk Projector Mount Quick Start Guide IPL T SF24 and SFI244Table of Contents Table of Contents, cont’d Introduction OneIPL T SF24 and SFI244 Introduction FeaturesAbout this Manual About the IPL T SF24 and SFI244 InterfacesEasily configured and controlled Installation and OperationTwo Introduction, cont’dInstallation Overview Installation and OperationIPL T SF24 and IPL T SFI244 Installation and Operation Mounting the IPL T InterfaceRear Panel Features and Cabling Installation and Operation, cont’dPower Furniture or projector mountingSerial communication Ethernet/LANOperation Front panel indicatorsIdentification Resetting the unit Three Connection and ConfigurationConnecting the Hardware Connection and Configuration, cont’dSerial connection Ethernet connectionPC configuration Configuring the HardwareIPL T interface configuration Flex I/O connectionArp -s 10.13.170.15 00-05-A6-00-0A-90 Configuring the IPL T using direct PC connectionPing Firmware upgrades Connection and Configuration, cont’dFour Communication and ControlPorts Overview Communication and Control, cont’dFlex I/O ports Digital inputDigital output Bidirectional serial control interface portsAnalog input Establishing or changing system or port settings Accessing and using the Web server Logon and system statusCommunication with the Interface Web serverControlling IR devices or sending IR commands SFI244 only 10 Web server System Settings screenCommunication and Control, cont’d Setting and changing your passwordsEditing and adding e-mail alerts Esc 4 SM Sending an e-mail alert through TelnetUpgrading the firmware Managing filesCreating a driver with the IR Learner software IR Learning SFI244 onlyProgrammer’s Guide for the Telnet and Web browser Using the command/response tableSymbol definitions Copyright information Password informationError responses 28 = Commands that may give E28 file not foundBidirectional Serial Data port Flex I/O Data portIR/Serial Data port SFI244 only IP Setup CommandsFirmware Version/Part Number/Information Re-map port designations File CommandsWeb Browser Specific MailCommunication and Control, cont’d Customization Reset ZAP/Erase CommandsServer side includes ControlCode examples Query stringExample 26c Browser view 28a Html source code using a query string 30b Browser view Href=index.html?cmd=W1*1*15*0irPlay/aReserved characters URL encodingUnsafe characters Communication and Control, cont’d Device Control Direct port access ports 2001 throughCustom Web pages Telnet PortPower connections TroubleshootingPort redirect Data connectionsAAppendix a Specifications, Part Numbers AccessoriesSpecifications Glossary AppendixBBParts Included partsGlossary GlossaryGlossary, cont’d