COMMAND
[PCLpPmmmabcde] [PCLpPmmm?]
[PCCpIii]
[PCCpOoo]
[PCCpPmmm]
[PCPDpxx]
[PRST]
35
DESCRIPTION
Loads ASCII command string to a preset up to 60 characters.
•Where
op = 2 for port 2, 3 for port 3 o mmm = 001 - 256 for preset
o abcdef… = hex string to be stored o abcdef - ?, queries current label
Note: When controlling Inline products that also use brackets as delimiters, replace open bracket [with ‘ and closed bracket] with " in the abcde… portion of the command. When this command is sent out the command port the ‘ " will automatically be replaced with [ ].
Forces command string loaded to a specific input to be sent.
•Where
op = 2 for port 2, 3 for port 3 o ii = 01 – 16 for input
Forces command string loaded to a specific output to be sent.
•Where
op = 2 for port 2, 3 for port 3 o oo = 01 – 16 for output
Forces command string loaded to a specific preset to be sent.
•Where
op = 2 for port 2, 3 for port 3 o mmm = 001 – 256 for preset
Sets projector code delay to a defined period.
•Where
op = 2 for port 2, 3 for port 3 o x = 0 for a 0 second delay o x = 1 for a 1 msec. delay o x = 2 for a 5 msec. delay o x = 3 for a 10 msec. delay o x = 4 for a 20 msec. delay o x = 5 for a 50 msec. delay
o x = 6 for a 100 msec. delay, x = ? to query
Resets all projector command codes to null.
Preset Commands
The MSX1616 has the ability to store and recall common configurations. Both units offer 256 presets available via serial control. The MSX3216 has 48 presets available via the front panel, while the MSX1616 has 32 presets available via the front panel.
COMMAND
[PSVxxx]
[PRCxxx]
DESCRIPTION
Save current configuration to preset memory.
•Where
oxxx = 001 – 256
Recall stores configuration from preset memory.
•Where
oxxx = 001 – 256
2002 - INLINE, INC. | MSX1616 OPERATION MANUAL - v1.0 5/8/02 |