Extron electronic MSX1616HR operation manual Installation and Safety Instructions

Page 2

Installation and Safety Instructions

For Models without a Power Switch:

The socket outlet shall be installed near the equipment and shall be accessible.

For all Models:

No serviceable parts inside the unit. Refer service to a qualified technician.

For Models with Internal or External Fuses:

For continued protection against fire hazard, replace only with same type and rating of fuse.

Instructions d’installation et de sécurité

Pour les modèles sans interrupteur de courant:

La prise de courant d’alimentation sera installé près de l’équipement et sera accessible.

Pour tout les modèles:

Pas de composants à entretenir à l’intérieur. Confiez toute réparation à un technicien qualifié.

Pour les modèles équipés de fusibles internes ou externes:

Afin d’éviter tout danger d’incendie, ne remplacer qu’avec le même type et la même valeur de fusible.

Installations- und Sicherheitshinweise

Für Geräte ohne Netzschalter:

Die Netzsteckdose soll in der Nähe des Gerätes installiert und frei zugänglich sein.

Für alle Geräte:

Keine Wartung innerhalb des Gerätes notwendig. Reparaturen nur durch einen Fachmann!

Für Geräte mit interner oder externer Sicherung:

Für dauernden Schutz gegen Feuergefahr darf die Sicherung nur gegen eine andere gleichen Typs und gleicher Nennleistung ausgewechselt werden.

Instalacion E Instrucciones de Seguridad

Modelos Sin Interruptor:

La conexión debe ser instalada cerca del equipo y debe ser accesible.

Para Todos Los Modelos:

Dentro de la unidad , no hay partes para reparar. Llame un tecnico calificado.

Modelos con Fusibles Internos o Externos:

Para prevenir un incendio, reemplace solo con el mismo tipo de fusible.

CE COMPLIANCE

All products exported to Europe by Inline, Inc. after January 1, 1997 have been tested and found to comply with EU Council Directive 89/336/EEC. These devices conform to the following standards:

EN50081-1 (1991), EN55022 (1987) EN50082-1 (1992 and 1994), EN60950-92

Shielded interconnect cables must be employed with this equipment to ensure compliance with the pertinent Electromagnetic Interference (EMI) and Electromagnetic Compatibility (EMC) standards governing this device.

FCC COMPLIANCE

This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide against harmful interference when equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their own expense.

Image 2
Contents MSX1616/MSX1616HR Installations- und Sicherheitshinweise Installation and Safety InstructionsInstructions d’installation et de sécurité Instalacion E Instrucciones de SeguridadTable of Contents Warranty Step MSX1616 Matrix Switcher Quick StartInstallation Front Panel Controls FunctionalityDescription Product FeaturesProduct Overview Dual Switching Modes MSX1616 model NumbersMounting the MSX1616 InstallationPower Connection Device ConnectionsFor Unbalanced Stereo Audio Input Video Input and Output ConnectionsAudio Input and Output Connections For Unbalanced Stereo Audio OutputSerial Ports DIP Switch Settings StandardHalf Duplex RS-485 Connection Diagram RS-232/422/485 ConnectionsDIP Switch Termination 2002 INLINE, INC Output CompatibilityInput  2002 INLINE, INC  2002 INLINE, INC Menu Enter Volume Take Cancel Blank Preset Input Output OperationFront Panel Operation Creating a Patch in Matrix ModeCreating Presets in Matrix Mode To confirm the patchRecalling Presets in Express Mode To recall a saved presetPreviewing Patches in Preview Mode Q2XW Hierarchy of LCD ScreensOr Out Menu ProgrammingLevel Selection Audio Setup Setting up Serial Ports Advanced MenuResetting the Switcher Activating RGB DelayControl Port Remote OperationCommunication Protocol Protocol StructureInput and Output Codes Preset CodesAuxiliary Ports 2 Serial Port Pin-outs ADDRxx Serial CommandsAddressing Commands ADDR@ ADDR?CPx@ CPx? Set-Up CommandsARC DFLTx FPx LBLIiiabcde… LBLOooabcde… RESxLVLx LVL?? LVLxyyy Level CommandsRGBxx VISx Example Switching CommandsTake MUTEoox Volume CommandsSsBLANKoo Mute MUTE?Volstop VOLL?VOLR? LVOL,? VINiix VINiixxxLMUTE,? LVOLR,? Auxiliary CommandsLVOLL,? PCPpxCommand Prst Preset CommandsPCCpIii PCCpOoo PCCpPmmm PCPDpxx PSVxxx PRCxxxPLBL1xxx? PLBL2xxx? PSV? Preset Label CommandsPSVxxx@  2002 INLINE, INC Warranty INLINE, Inc West Taft ORANGE, CA