Extron electronic MSX1616HR Auxiliary Ports 2, Input and Output Codes, Preset Codes

Page 26

24

The MSX1616 and MSX3216 offer command buffering. This allows you to send multiple commands to the unit with out a delay between each command. When you send a command, the unit responds R0. This indicates a valid command executed, followed by the original command and any other requested information.

Command

[MS1O02I01]

Meaning

Connect input 1 to output 2 at level 1

Response from unit

[R0 MS1O02I01]

Note: You may disable serial responses using RESx command.

Auxiliary Ports 2 and 3

The two auxiliary ports can store and transmit ASCII or Hex commands to control projectors, INLINE products, or other serially controlled A/V equipment. The baud rate of the auxiliary ports is selectable from 1200 to 38,400. The baud rate, parity, and stop bits can be changed individually for each port. You can make these changes using the $GYDQFHG menu option on the LCD on the front panel or via serial control using the [CPxbpsfd] command. Flow control and duplex parameters are predefined and have no affect on ports 2 or 3. The factory default communication parameters for the projector control ports are:

Communication Parameters

Baud rate

Parity

Data bits

Stop bits

Flow control

Duplex

9600

None

8

1

None

Full

The switcher can store ASCII or Hex command strings to an input, an output, or a preset. It can transmit these command strings out of the projector control port in two ways:

1.When an input to output switch occurs.

2.Using a serial command to force the string out, regardless of whether the switcher executed a switch.

Input and Output Codes

Each input and output can store one 60-character code for each auxiliary port. The switcher sends the output and input codes whenever you make a switch. The input code transmits first, followed by the output code.

Preset Codes

Each preset can store one 60-character code for each auxiliary port. When you recall a preset, the switcher sends the codes stored with that preset.

MSX1616 OPERATION MANUAL - v1.0 5/8/02

 2002 - INLINE, INC.

Image 26
Contents MSX1616/MSX1616HR Installations- und Sicherheitshinweise Installation and Safety InstructionsInstructions d’installation et de sécurité Instalacion E Instrucciones de SeguridadTable of Contents Warranty Step MSX1616 Matrix Switcher Quick StartInstallation Front Panel Controls FunctionalityDescription Product FeaturesProduct Overview Dual Switching Modes MSX1616 model NumbersMounting the MSX1616 InstallationPower Connection Device ConnectionsFor Unbalanced Stereo Audio Input Video Input and Output ConnectionsAudio Input and Output Connections For Unbalanced Stereo Audio OutputSerial Ports DIP Switch Settings StandardHalf Duplex RS-485 Connection Diagram RS-232/422/485 ConnectionsDIP Switch Termination 2002 INLINE, INC Output CompatibilityInput  2002 INLINE, INC  2002 INLINE, INC Menu Enter Volume Take Cancel Blank Preset Input Output OperationFront Panel Operation Creating a Patch in Matrix ModeCreating Presets in Matrix Mode To confirm the patchRecalling Presets in Express Mode To recall a saved presetPreviewing Patches in Preview Mode Q2XW Hierarchy of LCD ScreensOr Out Menu ProgrammingLevel Selection Audio Setup Setting up Serial Ports Advanced MenuResetting the Switcher Activating RGB DelayControl Port Remote OperationCommunication Protocol Protocol StructureInput and Output Codes Preset CodesAuxiliary Ports 2 Serial Port Pin-outs ADDRxx Serial CommandsAddressing Commands ADDR@ ADDR?CPx@ CPx? Set-Up CommandsARC DFLTx FPx LBLIiiabcde… LBLOooabcde… RESxLVLx LVL?? LVLxyyy Level CommandsRGBxx VISx Example Switching CommandsTake MUTEoox Volume CommandsSsBLANKoo Mute MUTE?Volstop VOLL?VOLR? LVOL,? VINiix VINiixxxLMUTE,? LVOLR,? Auxiliary CommandsLVOLL,? PCPpxCommand Prst Preset CommandsPCCpIii PCCpOoo PCCpPmmm PCPDpxx PSVxxx PRCxxxPLBL1xxx? PLBL2xxx? PSV? Preset Label CommandsPSVxxx@  2002 INLINE, INC Warranty INLINE, Inc West Taft ORANGE, CA