34
COMMAND
[PCHpIiiabcde] [PCHpIii?]
[PCHpOooabcde] [PCHpOoo?]
[PCHpPmmmabcde] [PCHpPmmm?]
[PCLpIiiabcde] [PCLpIii?]
[PCLpOooabcde] [PCLpOoo?]
DESCRIPTION
Loads hex command string to an input up to 60 characters.
•Where
op = 2 for port 2, 3 for port 3 o ii = 01 – 16 for input
o abcdef… = hex string to be stored o abcdef = ?, queries current label
Loads hex command string to an output up to 60 characters.
•Where
op = 2 for port 2, 3 for port 3 o oo = 01 – 16 for output
o abcdef… = hex string to be stored o abcdef - ?, queries current label
Loads hex command string to a preset up to 60 characters.
•Where
op = 2 for port 2, 3 for port 3 o mmm = 001 - 256 for preset
o abcdef… = hex string to be stored o abcdef - ?, queries current label
Loads ASCII command string to an input up to 60 characters.
•Where
op = 2 for port 2, 3 for port 3 o ii = 01 – 16 for input
o abcdef… = hex string to be stored o abcdef - ?, queries current label
Note: When controlling Inline products that also use brackets as delimiters, replace open bracket [ with ‘ and closed bracket ] with " in the abcde… portion of the command. When this command is sent out the command port the ‘will automatically be replaced with []. "
Loads ASCII command string to an output up to 60 characters.
•Where
op = 2 for port 2, 3 for port 3 o oo = 01 – 16 for output
o abcdef… = hex string to be stored o abcdef - ?, queries current label
Note: When controlling Inline products that also use brackets as delimiters, replace open bracket [with ‘ and closed bracket] with " in the abcde… portion of the command. When this command is sent out the command port the ‘ " will automatically be replaced with [ ].
MSX1616 OPERATION MANUAL - v1.0 5/8/02 | 2002 - INLINE, INC. |