Extron electronic SWP123 manual Front Panel Operation, Miscellaneous controls and features

Page 19

Miscellaneous controls and features

9Microphone Talk Over button — This button turns on the microphone mixer to provide microphone talk-over for the Master Audio. The LED, when lit, indicates that the microphone mixer is turned on.

10Mic Level — Use the increment () and decrement () buttons to adjust the volume of the microphone.

11Mute — This button mutes the Master Audio output. The LED, when lit, indicates that the Master Audio output is muted.

12AV Volume — Use the increment () and decrement () buttons to adjust the volume of the Master Audio output.

13IR Window — Receives IR commands from the optional CTL 120-3 IR remote control.

Front Panel Operation

The functions of the front panel controls are described in the following sections.

Selecting A/V inputs to output

There are four input selection groups on the front panel: VGA/Audio, S-video/ Audio, Composite Video/Audio, and Master Audio. These groups correspond to the four independent switchers (three A/V and one audio only) in the SWP 123 Presentation Switcher.

Use the four input select buttons in each A/V group to route a video signal to the output for each group. When you press an input select button, the green LED indicator on top of the button lights, indicating which input is linked to the output for that group. To select a different input for that group, press a different button in the same group.

The outputs of all three A/V groups are always active within the group. The audio output from any group (or the microphone) may be routed to the Master Audio switcher for output. See the Master Audio functions section (below) for more details.

There are two switcher modes available for the SWP123: Separate switcher mode and Single switcher mode. The default is Separate switcher mode.

Separate switcher mode

In this mode, all three A/V groups operate independently from each other, and all three outputs (audio and video) are active.

Single switcher mode

This mode can be turned on/off only via RS-232. In this mode, all three A/V groups operate as a combined 12 x 1 switcher (12 inputs and one output). Only the output (audio and video) of the selected A/V group is active, while the remaining two unselected A/V group outputs are muted. This design feature enables the autoswitching feature of the output device (scaler, etc.).

Blanking the output from a group

Each A/V group has a blank button. To blank the video output for a group, press the Blank button for the group. The LED above the button lights, indicating that blanking is active.

SWP123 Presentation Switchers • Operation

3-3

Image 19
Contents SWP123 Presentation SwitcherSicherheitsanleitungen Deutsch PrecautionsSafety Instructions English Consignes de Sécurité FrançaisQuick Start SWP123 SWP123 Presentation Switcher Quick Start QS-1Rack mounting the SWP123 Quick Start SWP123, cont’d QS-2 SWP123 Presentation Switcher Quick StartTable of Contents Table of Contents, cont’d Introduction OneIntroduction About the SWP123 Presentation SwitcherSWP123 Switcher Features SWP123 Presentation Switcher IntroductionSWP123 Presentation Switcher Introduction Introduction, cont’d Two InstallationTabletop use InstallationMounting the Switcher SWP123 Presentation Switcher InstallationRear panel of the SWP123 Rear Panel ConnectorsConnecting the SWP123 Switcher Installation, cont’dAudio input and output Connecting the unbalanced audio inputConnecting the balanced audio output Connecting the unbalanced audio outputThree MVP 104GX InstallationOperation Video/Audio Select groups Front Panel FeaturesSWP123 Presentation Switcher Operation OperationBlanking the output from a group Miscellaneous controls and featuresFront Panel Operation Selecting A/V inputs to outputMaster Audio functions Operation, cont’dMicrophone controls +24V Phantom Power switch Wiring the decoder loopDecoder Loop Function This page was intentionally left blank Windows-Based Control Program FourMVP 104 Operation Windows-Based Control Program, cont’d Installing the Windows-based ICS100 Control SoftwareUsing the Software Specifying your switcher modelDefining input icons and labels Using the Control PanelBlanking the output of a group Adjusting the Master Audio or Microphone audio levelEnabling audio-follow-video switching Selecting a new inputUsing Terminal Comm Setting audio gain input to Master Audio outputEnabling/disabling front panel control SWP123 Presentation Switcher Windows-Based Control Program Resetting the unitICS100 Control Program Help Five Remote ControlMVP 104 Windows Control Program SWP123 Presentation Switcher Remote Control DIP switch settingsUsing the command tables Host-to-Switcher CommunicationsAddressing commands Setup commands Remote Control, cont’dSwitching commands Mute/un-mute Volume commandsStop volume ramp Adjust volume level-rightSet volume level-right Ramp volume levelEnabling remote control of the switcher over a network Remote Control from a NetworkConfiguring the client remote PC Configuring the server local PC10 SWP123 Presentation Switcher Remote Control Adjusting response timeStopping communication Switching input devices CTL120-3 IR Remote Control12SWP123 Presentation Switcher Remote Control Resetting the component codeAAppendix SpecificationsMVP 104 Programmer’s Guide SWP123 Presentation Switcher Specifications SpecificationsAudio master SWP123 Presentation Switcher SpecificationsMaster audio output Specifications, cont’dReference Information BAppendixReference Information SWP123 Presentation Switcher Reference InformationUpdating the Firmware Cables SWP123 switcher part numbersOptional accessories Part NumbersPre-cut cables Reference Information, cont’dExtron Part Part number BNC-5 Mini HR Cable FCC Class a Notice Extron’s Warranty Extron Electronics, USA