Extron electronic SWP123 manual Windows-Based Control Program, cont’d, Using the Software

Page 24

Windows-Based Control Program, cont’d

The ICS100 Control Software, which can be used to control the SWP123 Presentation Switcher, requires Windows 95/98, NT, or later. The program provides control of the switcher’s functions from a PC. Control is enabled by connecting the switcher to a PC with a serial cable (to the Serial Port connector), then installing and configuring the ICS100 Control Software program in the PC. For information on remotely controlling the switcher from a network, see “Remote Control from a Network”, in chapter 5, Remote Control.

Installing the Windows®-based ICS100 Control Software

The program is contained on a single CD, provided with your switcher. The program occupies approximately 2.5 MB (megabytes) of hard drive space. Run the program from the hard drive after installation.

To install the software from the CD onto the hard drive, put the CD in the CD-ROM drive of your PC. The install program automatically appears. Follow the instructions on the screen.

By default, the Windows installation creates a C:\Program Files\Extron directory, and it places an ICS100 icon on your Windows desktop.

Using the Software

Running the control program

1. To run the ICS100 Control program, double-click on the ICS100 icon your Windows desktop.

The ICS interface screen is displayed.

Figure 4-1 — ICS100 interface screen

Specifying your switcher model

The ICS100 Control Program normally detects your switcher model automatically. If not:

1.From the Inline Model menu, select the switcher model you want to control.

2.Use the other menus to access optional device settings. The Controls, Options, and Communications menus will change depending on which switcher model you selected on the Inline Model menu.

4-2 SWP123 Presentation Switcher • Windows-Based Control Program

Image 24
Contents Presentation Switcher SWP123Precautions Safety Instructions EnglishConsignes de Sécurité Français Sicherheitsanleitungen DeutschSWP123 Presentation Switcher Quick Start QS-1 Quick Start SWP123Rack mounting the SWP123 QS-2 SWP123 Presentation Switcher Quick Start Quick Start SWP123, cont’dTable of Contents Table of Contents, cont’d One IntroductionAbout the SWP123 Presentation Switcher SWP123 Switcher FeaturesSWP123 Presentation Switcher Introduction IntroductionSWP123 Presentation Switcher Introduction Introduction, cont’d Installation TwoInstallation Mounting the SwitcherSWP123 Presentation Switcher Installation Tabletop useRear Panel Connectors Rear panel of the SWP123Installation, cont’d Connecting the SWP123 SwitcherConnecting the unbalanced audio input Audio input and outputConnecting the unbalanced audio output Connecting the balanced audio outputMVP 104GX Installation ThreeOperation Front Panel Features SWP123 Presentation Switcher OperationOperation Video/Audio Select groupsMiscellaneous controls and features Front Panel OperationSelecting A/V inputs to output Blanking the output from a groupOperation, cont’d Master Audio functionsMicrophone controls Wiring the decoder loop +24V Phantom Power switchDecoder Loop Function This page was intentionally left blank Four Windows-Based Control ProgramMVP 104 Operation Installing the Windows-based ICS100 Control Software Using the SoftwareSpecifying your switcher model Windows-Based Control Program, cont’dUsing the Control Panel Defining input icons and labelsAdjusting the Master Audio or Microphone audio level Enabling audio-follow-video switchingSelecting a new input Blanking the output of a groupSetting audio gain input to Master Audio output Using Terminal CommEnabling/disabling front panel control Resetting the unit SWP123 Presentation Switcher Windows-Based Control ProgramICS100 Control Program Help Remote Control FiveMVP 104 Windows Control Program DIP switch settings SWP123 Presentation Switcher Remote ControlHost-to-Switcher Communications Using the command tablesAddressing commands Remote Control, cont’d Setup commandsSwitching commands Volume commands Mute/un-muteAdjust volume level-right Set volume level-rightRamp volume level Stop volume rampRemote Control from a Network Enabling remote control of the switcher over a networkConfiguring the server local PC Configuring the client remote PCAdjusting response time 10 SWP123 Presentation Switcher Remote ControlStopping communication CTL120-3 IR Remote Control Switching input devicesResetting the component code 12SWP123 Presentation Switcher Remote ControlSpecifications AAppendixMVP 104 Programmer’s Guide Specifications SWP123 Presentation Switcher SpecificationsSWP123 Presentation Switcher Specifications Audio masterSpecifications, cont’d Master audio outputBAppendix Reference InformationSWP123 Presentation Switcher Reference Information Reference InformationUpdating the Firmware SWP123 switcher part numbers Optional accessoriesPart Numbers CablesReference Information, cont’d Pre-cut cablesExtron Part Part number BNC-5 Mini HR Cable FCC Class a Notice Extron’s Warranty Extron Electronics, USA