Operation, cont’d

Master Audio functions

Master Audio is a separate audio output from the A/V groups. Master Audio can route audio from any of the groups or from a microphone to the Master Audio output.

Master Audio volume and individual audio input attenuation does not affect microphone volume.

Selecting an input for the Master Audio switcher

Select audio input from any of the A/V groups or from the microphone by pressing one of the Master Audio Select buttons (VGA, S-video, Video, or Mic). An LED lights to indicate the selected input.

Increasing or decreasing the Master Audio volume

To increase or decrease the Master Audio volume, press the AV Volume increment () and decrement () buttons until the desired sound level is reached.

Increasing or decreasing individual audio input attenuation adjustments

To equalize all audio input sources, audio inputs can be adjusted individually.

1.Press and hold the input button that corresponds to the input device whose volume you want to adjust.

2.Press the volume increment () and decrement () buttons until the desired sound level is reached.

Master Audio volume and individual audio input attenuation does not affect microphone volume.

Muting and unmuting the audio

To mute the Master Audio output, press the Mute button. The LED over the Mute button lights to indicate that Mute is active. To unmute the audio, press the Mute button again; the LED goes out.

Microphone controls

Microphone Talk Over button

To mix the microphone input with the Master Audio output (“talk-over” mode), press the Microphone Talk Over button. The indicator LED above the button lights when Microphone Talk Over is on. Press the Microphone Talk Over button again to unmix the output. In “talk-over” mode, the main audio level is lowered when the microphone picks up speech.

Mic Level buttons

To increase or decrease the microphone volume, press the Mic Level increment () and decrement () buttons until the desired sound level is reached.

Mic Level does not affect Master Audio volume.

Setting microphone talk over threshold

1.Finish installation wiring and setup as described in the previous sections.

2.Turn on the microphone by pressing the Microphone Talk Over button.

3.Speak into the microphone in a normal voice. The main program audio level should drop moderately. If not, lower the threshold by turning the Talk Over Threshold Adjust pot on the back panel of the switcher clockwise in small increments.

3-4 SWP123 Presentation Switcher • Operation

Image 20
Contents Presentation Switcher SWP123Precautions Safety Instructions EnglishConsignes de Sécurité Français Sicherheitsanleitungen DeutschRack mounting the SWP123 SWP123 Presentation Switcher Quick Start QS-1Quick Start SWP123 QS-2 SWP123 Presentation Switcher Quick Start Quick Start SWP123, cont’dTable of Contents Table of Contents, cont’d One IntroductionAbout the SWP123 Presentation Switcher SWP123 Switcher FeaturesSWP123 Presentation Switcher Introduction IntroductionSWP123 Presentation Switcher Introduction Introduction, cont’d Installation TwoInstallation Mounting the SwitcherSWP123 Presentation Switcher Installation Tabletop useRear Panel Connectors Rear panel of the SWP123Installation, cont’d Connecting the SWP123 SwitcherConnecting the unbalanced audio input Audio input and outputConnecting the unbalanced audio output Connecting the balanced audio outputOperation MVP 104GX InstallationThree Front Panel Features SWP123 Presentation Switcher OperationOperation Video/Audio Select groupsMiscellaneous controls and features Front Panel OperationSelecting A/V inputs to output Blanking the output from a groupMicrophone controls Operation, cont’dMaster Audio functions Decoder Loop Function Wiring the decoder loop+24V Phantom Power switch This page was intentionally left blank MVP 104 Operation FourWindows-Based Control Program Installing the Windows-based ICS100 Control Software Using the SoftwareSpecifying your switcher model Windows-Based Control Program, cont’dUsing the Control Panel Defining input icons and labelsAdjusting the Master Audio or Microphone audio level Enabling audio-follow-video switchingSelecting a new input Blanking the output of a groupEnabling/disabling front panel control Setting audio gain input to Master Audio outputUsing Terminal Comm ICS100 Control Program Help Resetting the unitSWP123 Presentation Switcher Windows-Based Control Program MVP 104 Windows Control Program Remote ControlFive DIP switch settings SWP123 Presentation Switcher Remote ControlAddressing commands Host-to-Switcher CommunicationsUsing the command tables Remote Control, cont’d Setup commandsSwitching commands Volume commands Mute/un-muteAdjust volume level-right Set volume level-rightRamp volume level Stop volume rampRemote Control from a Network Enabling remote control of the switcher over a networkConfiguring the server local PC Configuring the client remote PCStopping communication Adjusting response time10 SWP123 Presentation Switcher Remote Control CTL120-3 IR Remote Control Switching input devicesResetting the component code 12SWP123 Presentation Switcher Remote ControlMVP 104 Programmer’s Guide SpecificationsAAppendix Specifications SWP123 Presentation Switcher SpecificationsSWP123 Presentation Switcher Specifications Audio masterSpecifications, cont’d Master audio outputBAppendix Reference InformationUpdating the Firmware SWP123 Presentation Switcher Reference InformationReference Information SWP123 switcher part numbers Optional accessoriesPart Numbers CablesExtron Part Part number BNC-5 Mini HR Cable Reference Information, cont’dPre-cut cables FCC Class a Notice Extron’s Warranty Extron Electronics, USA