Extron electronic manual Audio master, SWP123 Presentation Switcher Specifications

Page 43

Output level

TTL: 4 V to 5 Vp-p, unterminated

Input impedance

510 ohms

Output impedance

75 ohms

Max input voltage

5 Vp-p

Max. propagation delay

8 ns

Max. rise/fall time

28 ns

Polarity

Positive or negative (follows input)

Audio — master

Gain

Unbalanced output: 0 dB; balanced output: +6 dB

Frequency response

10 Hz to 175 kHz, -3 dB

 

20 Hz to 20 kHz, ±0.05 dB

THD + Noise

<0.06% @ 1 kHz at nominal level

S/N

>87.0 dB at maximum output

Audio — individual audio groups (VGA, S-video, composite video)

Gain

Unbalanced output: 0 dB; balanced output: +6 dB

Frequency response

10 Hz to 175 kHz, -3 dB

 

20 Hz to 20 kHz, ±0.05 dB

THD + Noise

<0.03% @ 1 kHz at nominal level

S/N

>87.0 dB at maximum output

Crosstalk

<-89 dB @ 1 kHz

Stereo channel separation

>89 dB @ 1 kHz

CMRR

>60 dB @ 20 Hz to 20 kHz

Audio input — individual audio groups (VGA, S-video, composite video)

Number/signal type

4 sets of stereo, unbalanced inputs per group (12 inputs total)

Connectors

4 pairs of female RCA connectors per group

Impedance

>20k ohms unbalanced, DC coupled

Nominal level

-10 dBV (316 mV)

Maximum level

+18 dBu, (balanced or unbalanced) at 1%THD+N

Input gain

 

Input to Master output ...

-64 dB to 0 dB, adjustable per input

Input to group output

Unity

0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV 2 dBu

Audio output — individual audio groups (VGA, S-video, composite video)

Number/signal type

1 passive, local, stereo, balanced/unbalanced per each group

Connectors

(1) 3.8 mm captive screw connector, 5 pole, per each group

Impedance

50 ohms unbalanced, 100 ohms balanced

Gain error

±0.01 dB channel to channel

Maximum level (Hi-Z)

>+24 dBu, balanced at 1%THD+N

Maximum level (600 ohm)

>+18 dBm, balanced at 1%THD+N

Microphone input

Number/type

1 mono, balanced

Connectors

1 XLR female

Impedance

1.8k ohms, balanced/unbalanced

Nominal level

-48 dBV (1 mV)

Minimum level

-72 dBV (0.25 mV)

SWP123 Presentation Switcher • Specifications

A-3

Image 43
Contents SWP123 Presentation SwitcherSicherheitsanleitungen Deutsch PrecautionsSafety Instructions English Consignes de Sécurité FrançaisQuick Start SWP123 SWP123 Presentation Switcher Quick Start QS-1Rack mounting the SWP123 Quick Start SWP123, cont’d QS-2 SWP123 Presentation Switcher Quick StartTable of Contents Table of Contents, cont’d Introduction OneIntroduction About the SWP123 Presentation SwitcherSWP123 Switcher Features SWP123 Presentation Switcher IntroductionSWP123 Presentation Switcher Introduction Introduction, cont’d Two InstallationTabletop use InstallationMounting the Switcher SWP123 Presentation Switcher InstallationRear panel of the SWP123 Rear Panel ConnectorsConnecting the SWP123 Switcher Installation, cont’dAudio input and output Connecting the unbalanced audio inputConnecting the balanced audio output Connecting the unbalanced audio outputThree MVP 104GX InstallationOperation Video/Audio Select groups Front Panel FeaturesSWP123 Presentation Switcher Operation OperationBlanking the output from a group Miscellaneous controls and featuresFront Panel Operation Selecting A/V inputs to outputMaster Audio functions Operation, cont’dMicrophone controls +24V Phantom Power switch Wiring the decoder loopDecoder Loop Function This page was intentionally left blank Windows-Based Control Program FourMVP 104 Operation Windows-Based Control Program, cont’d Installing the Windows-based ICS100 Control SoftwareUsing the Software Specifying your switcher modelDefining input icons and labels Using the Control PanelBlanking the output of a group Adjusting the Master Audio or Microphone audio levelEnabling audio-follow-video switching Selecting a new inputUsing Terminal Comm Setting audio gain input to Master Audio outputEnabling/disabling front panel control SWP123 Presentation Switcher Windows-Based Control Program Resetting the unitICS100 Control Program Help Five Remote ControlMVP 104 Windows Control Program SWP123 Presentation Switcher Remote Control DIP switch settingsUsing the command tables Host-to-Switcher CommunicationsAddressing commands Setup commands Remote Control, cont’dSwitching commands Mute/un-mute Volume commandsStop volume ramp Adjust volume level-rightSet volume level-right Ramp volume levelEnabling remote control of the switcher over a network Remote Control from a NetworkConfiguring the client remote PC Configuring the server local PC10 SWP123 Presentation Switcher Remote Control Adjusting response timeStopping communication Switching input devices CTL120-3 IR Remote Control12SWP123 Presentation Switcher Remote Control Resetting the component codeAAppendix SpecificationsMVP 104 Programmer’s Guide SWP123 Presentation Switcher Specifications SpecificationsAudio master SWP123 Presentation Switcher SpecificationsMaster audio output Specifications, cont’dReference Information BAppendixReference Information SWP123 Presentation Switcher Reference InformationUpdating the Firmware Cables SWP123 switcher part numbersOptional accessories Part NumbersPre-cut cables Reference Information, cont’dExtron Part Part number BNC-5 Mini HR Cable FCC Class a Notice Extron’s Warranty Extron Electronics, USA