ATTO Technology 2370E Performance, Ping, ReadOnlyPassword, ReadOnlyUsername, Reserve

Page 42

MinOpTemp (FB2390, FB2400 only) Regulates/displays the minimum enclosure temperature alarm of the FibreBridge in degrees Celsius.Valid entries are between 0 degrees and 15 degrees

Default: 0

set MinOpTemp [0-15]

Requires a SaveConfiguration Restart command get MinOpTemp

OpTempWarn (FB2390, FB2400 only) Regulates/displays the number of degrees in Celsius before a warning is sent to the user. Valid entries are between 0 degrees and 15 degrees

Default: 5

set OpTempWarn [0-15]

Requires a SaveConfiguration Restart command get OpTempWarn

Password

Specifies password for all non-serial sessions: Telnet, FTP and ExpressNAV interface. You are prompted for the current password, to enter the new password, and to confirm the new password. If local Echo is enabled, password echoes all * characters. If VerboseMode has been enabled, CLI requests that you re-enter the password. When the password is all 0s, Telnet and FTP do not validate the password and MD5 authentication is disabled.Configure an empty password by pressing the Enter key when prompted for the new password and the new password confirmation.Passwords are case sensitive and can be 1-32 characters long with no spaces.

Default: Password set Password

Requires a SaveConfiguration command

Performance

Returns the performance data for the FC port you specify. Data includes the average rate (MB per sec.) and number of I/Os measured over the previous sampling period where a sampling period is approximately one second. Successful SCSI Read (08h, 28h) and Write (0ah, 2Ah) commands are considered I/Os.Reported performance may be affected by FC port and SCSI bus availability and saturation, SCSI device speeds and overall system use.

get Performance <fp>

Ping

Sends an ICMP echo request to the specified host.

Ping [mp1] [xxx.xxx.xxx.xxx] <count <size>>

xi

ReadOnlyPassword

Specifies password for all non-serial sessions: Telnet, FTP and ExpressNAV interface. ReadOnlyPassword is case sensitive, 0 to 32 characters, and cannot contain spaces. Configure an empty password by not specifying one.

Default: Password

set ReadOnlyPassword

Requires a SaveConfiguration command

ReadOnlyUsername

Specifies user name for all Telnet, FTP and ExpressNAV user management console sessions. Username is case insensitive, 1-32 characters, no spaces.

Default: User

set ReadOnlyUsername

Requires a SaveConfiguration command get ReadOnlyUsername

Reserve

Prevents other CLI sessions from modifying the FibreBridge. When the FibreBridge services interface is reserved, set commands are unavailable but get commands are available. At least one service interface always has access to the FibreBridge at all times. This interface always reports RELEASED status, since it may issue set commands. Reservation of the FibreBridge is implicit: if the configuration is changed by any user of CLI sessions, the FibreBridge becomes RESERVED. Executing a SaveConfiguration command, RestoreConfiguration or FirmwareRestart forced releases the FibreBridge so that other devices may modify it.

Reserve

Reset FCPortErrors

Resets all FC error counts for the specified port to zero. Refer to FCPortErrors.

command: ResetFCPortErrors [fp all]

RestoreConfiguration

Restores configuration to either the default configuration or the configuration last saved into non-volatile memory. The saved option undoes any changes made since the last save.

RestoreConfiguration [Default Saved]

ATTO Technology Inc. FibreBridge Installation and Operation Manual

Image 42
Contents Atto FibreBridge Atto Technology, Inc Contents Map devices Installing the FibreBridgeConfiguring the FibreBridge Remote monitoring, managementAppendix D Warranty information Xix Atto FibreBridge 2370E features, benefits Atto FibreBridge provides storage optionsAtto FibreBridge 2390C/R/D features, benefits Atto FibreBridge 2400C/R/D features, benefitsAtto FibreBridge 2370E LED Header P5 Pins LED Header P6 PinsAtto FibreBridge 2390R/D DimensionsOperating temperature 0-40 C external Fibre Channel interfaceManual reset switch LEDs on the front panel areInput voltage Power draw 30 Watts Atto FibreBridge 2390CHeight of tallest component .545 inches Page Atto FibreBridge 2400R/D Input voltage 100-240 VAC 1.7-.7A 50- 60HzLEDs on the faceplate are Power Atto FibreBridge 2400CInches Install the FibreBridge Install the FibreBridgeUnpack the packing box verify contents Discover the IP addressClick on Launch Browser Internet Explorer setupBegin initial configuration Select Internet OptionsModify passwords Configure the FibreBridgePort configurations Preliminary stepsEnhance performance ManagementMap devices FibreBridge mappingScsi device mapping Multiple Node addressing FB2400 only Mapping devices automaticallyMapping devices manually Remote monitoring, management Remote Management page appears Traps disabledSNMP-based monitoring Event Severity Extended ExplanationEmail messages provide error notification Vdda Vddb Vddc VdddEvent Severity Explanation Using FTP Update firmwareUsing ExpressNAV Using the zModem commandClick Send File Interface options Using ExpressNAVUsing the serial port Opening an ExpressNAV sessionUsing Telnet EnterFibre Channel connections Appendix a CablingScsi port connections Serial port connectionsCommand conventions Symbol Indicates Appendix B CLI provides ASCII-based interfaceCLI error messages Command Default ExampleCLI summary reference Ipdhcp Snmp Command explanations DisplayEventLogFilter DumpConfigurationDisplayEventLog DisplayTraceLogEmailServerAddress EmailPasswordEmailNotifyAddress EmailUsernameFCHardAddress FCPortErrorsFCHard FCMultiNode FB2400 onlyIdentifyBridge FirmwareRestartHelp InfoReset FCPortErrors PasswordReadOnlyPassword RestoreConfigurationSCSIPortResetOnStartup SaveConfigurationSCSIPortReset RouteSCSIPortTermination SerialPortBaudRateSerialPortEcho SCSIPortWideTransferSNMPTraps SpeedWriteDefaultSNMPTrapAddress SNTPServerTraceLogFilter TimeZoneTraceLog UsernameZModem Appendix C Standards and compliances Declaration of ConformityCertification for the FibreBridge 2400 only Appendix D Warranty information

2400C/R/D, 2390C/R/D, 2370E specifications

ATTO Technology is a well-recognized name in the field of high-performance data storage and networking. Among its range of products, the ATTO 2390C/R/D, 2400C/R/D, and 2370E stand out due to their innovative features and advanced technologies tailored for demanding data environments. These devices are specifically designed for applications including digital media, video editing, and data-intensive tasks where speed and reliability are paramount.

The ATTO 2390 Series incorporates advanced features aimed at maximizing performance. One of its key characteristics is the support for multi-channel connectivity, which allows users to connect multiple systems and devices simultaneously. This is particularly beneficial in high-bandwidth applications where multiple data streams are processed simultaneously. In addition, the 2390 models feature a robust cache management system that accelerates data transfer rates, significantly reducing latency and enhancing overall efficiency.

The ATTO 2400 Series further enhances data management capabilities by supporting the latest protocol standards. This ensures compatibility with a wide range of storage systems and infrastructures, providing users with flexibility in their IT setups. Moreover, the 2400 models are optimized for PCIe Gen 4 technology, which delivers impressive throughput rates that cater to the most demanding applications, including 4K and 8K video editing.

The ATTO 2370E takes a slightly different approach, focusing on compatibility and scalability. Designed for high-performance computing environments, it features versatile connection options, including both SAS and SATA interfaces. This not only ensures high data transfer rates but also makes the device adaptable to various storage architectures, whether for entry-level consumers or enterprise solutions.

All three series integrate ATTO's proprietary Advanced Data Streaming (ADS) technology, allowing for smoother workflow by managing data transfers and reducing the bottleneck in high-load scenarios. This capability is essential for content production environments where seamless data handling is crucial.

In conclusion, the ATTO Technology 2390C/R/D, 2400C/R/D, and 2370E are pivotal in enhancing data storage solutions in today's fast-paced digital landscape. Combining high performance, compatibility with modern protocols, and intelligent data management features, these products are designed to meet the needs of professionals in media, entertainment, and enterprise sectors alike. With ATTO's commitment to innovation, users can expect reliable and efficient services that drive their productivity and workflow.