Tripp Lite UL1778 Storage, Service, Battery Replacement Door, Automatic Voltage Regulation

Page 7

200208108 93-2089 OmniSmart725 Owner’s Manual.qxd 9/12/2002 9:22 AM Page 7

Basic Operation continued

NORM DELAY

Battery Replacement Door

Under normal conditions, the original battery in your UPS will last several years. Battery replacement should be performed only by qualified service personnel. Refer to “Battery Warnings” in the Safety section on page 2.

Power Sensitivity/Lowline Adjustment

This dial is normally set fully counterclockwise, which enables the UPS to protect against waveform distortions in its AC input. When such distortion occurs, the UPS will normally switch to providing PWM sinewave power from its battery reserves for as long as the distortion is present. In some areas with poor utility power or where the UPS’s input power comes from a backup generator, frequent brownouts and/or chronic waveform distortion could cause the UPS to switch to battery too often, draining its battery reserves. You may be able to reduce how often your UPS switches to battery due to waveform distortion or brownouts by experimenting with different settings for this dial. As the dial is turned clockwise, the UPS becomes more tolerant of variations in its input power’s AC waveform and reduces the voltage point at which it switches to battery. NOTE: The further the dial is adjusted clockwise, the greater the degree of waveform distortion and the lower the input voltage the UPS will allow to pass to connected equipment. When experimenting with different settings for this dial, operate connected equipment in a safe test mode so that the effect on the equipment of any waveform distortions in the UPS’s output can be evaluated without disrupting critical operations. The experiment should last long enough to assure that all expected line conditions are encountered.

Automatic Voltage Regulation

During brownouts, your UPS will automatically correct low AC line voltage. When automatic voltage regulation is operating, your UPS may be heard to click gently. This is a normal, automatic operation of your UPS, and no action is required on your part.

Storage & Service

Storage

All connected equipment should be turned off, then disconnected from the UPS to avoid battery drain. Unplug your UPS from its AC receptacle, then press and hold its ON/OFF button to deactivate it. Your UPS is now ready for storage. If you plan on storing your UPS for an extended period of time, fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet and letting the UPS charge for 4 to 6 hours. If you leave your UPS batteries discharged for an extended period of time, they will suffer a permanent loss of capacity.

Service

If returning your UPS for service, contact your local Tripp Lite dealer or distributor. They will refer you to a service center. Please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit. Enclose a letter describing the symptoms of the problem. If the UPS is within the warranty period, enclose a copy of your sales receipt.

7

Image 7
Contents OmniSmart & SmartPro USB UPS Connection Warnings Important Safety InstructionsBattery Warnings UPS Location WarningsConnect your UPS to An electrical outlet Select UPS Operating ModeButtons Quick Installation optionalPhone Line/Network Line Surge Suppression USB CommunicationsBasic Operation Telephone/Network Protection Jacks Select models only Indicator LightsOther UPS Features AC ReceptaclesStorage ServiceBattery Replacement Door Power Sensitivity/Lowline AdjustmentAGSM500USBKJR6 AGOM1000USBKSR6 Manual de operación Advertencias sobre la conexión de equipos Importantes instrucciones de seguridadAdvertencias sobre la ubicación del UPS Advertencias sobre la conexión del UPSSelección del modo de operación del UPS Conecte el sistema UPS a una toma de corrienteBotones Instalación rápida optativoSupresión de sobretensión en las líneas telefónica y de red Comunicaciones USBModo Charge only carga solamente Deshabilita el Operación básica continuaciónOtras prestaciones del UPS Luces indicadorasNorm Delay Servicio AlmacenamientoGuide de lutilisateur Mises en garde relatives au raccord de léquipement Mises en garde relatives à lemplacement du système UPSImportantes consignes de sécurité Mises en garde relatives au raccord du système UPSBranchez votre système UPS dans une prise de secteur Choix du mode dexploitation du système UPSCommunications USB Installation rapide facultativeCommutateurs Exploitation de base suite Mode Charge only Active la batterie de secours. État duAutres fonctions Voyants lumineuxPrises c.a Port USB Porte de remplacement de la batterieRégulation de tension automatique Entretien Entreposage