Accessory Slot: Remove the small cover panel from this slot to install optional accessories to remotely monitor and control your UPS. Refer to your accessory’s manual for installation instructions. Contact Tripp Lite Customer Support at

(773)869-1234 for more information, including a list of available SNMP, network management and connectivity products.

Power Sensitivity Adjustment (Select Models): This dial is normally set fully counter-clockwise, which enables the UPS to provide maximum protection against waveform distortions in its AC input. When such distortion occurs, the UPS will normally switch to providing sine wave power from its battery reserves for as long as the distortion is present. In areas with poor utility power or where the UPS’s input power comes from a backup generator, chronic waveform distortion could cause the UPS to switch to battery too frequently, draining its battery reserves. You may be able to reduce how often your UPS switches to battery due to moderate waveform distortion by experimenting with different settings for this dial. As the dial is turned clockwise, the UPS becomes more tolerant of variations in its input power’s AC waveform. NOTE: The further the dial is adjusted clockwise, the greater the degree of waveform distortion the UPS will allow to pass to connected equipment. When experimenting with different settings for this dial, operate connected equipment in a safe test mode so that the effect on the equipment of any waveform distortions in the UPS’s output can be evaluated without disrupting critical operations.

External Battery Connector (Select Models Only): Use to connect Tripp Lite external battery packs for additional runtime. The specifications section of this manual lists the Tripp Lite external battery packs that are compatible with your model. Refer to instructions available with the battery pack for complete con- nection information and safety warnings.

Input Breaker(s) (all models): Protect your electrical circuit from overcurrent draw from the UPS load. If these breakers trip, remove some of the load; then reset them by pressing the breaker(s) in.

Output Breaker(s) (select models): Protect your UPS from output overload. If one or more breakers trip, remove some of the load on the circuit(s), then reset them by pressing the breaker switch(es) in.

Ground Screw: Use this to connect any equipment that requires a chassis ground.

10

Image 10
Contents Intelligent, Line-Interactive UPS Systems SMX500RT1U SMX750RT1U SMX1000RT2UUPS Location Warnings Important Safety InstructionsBattery Warnings UPS Connection WarningsMounting Rack Post MountingMounting Tower Post Telecom MountingTurn the UPS on External Battery Connection select models Buttons Front Panel Indicator Lights Front Panel Other UPS Features Rear Panel Basic Operation Service StorageProcedure OutputManual del propietario Sistemas de UPS Inteligentes e Interactivos en LíneaAdvertencias sobre la conexión del UPS Instrucciones de seguridad importantesAdvertencias sobre la ubicación del UPS Advertencias sobre la conexión de equiposMontaje Bastidor Montaje de 4 postesMontaje de 2 postes Telecomunicaciones Montaje en bastidor continúaMontaje En torre Tolos los modelos de UPSEn el enchufe de toma eléctrica C.A Encienda el UPSConexión de puerto EPO todos los modelos Comunicaciones USB y serie RS-232 todos los modelosConexión de batería externa modelos exclusivos Botones Panel frontal Botón ON/OFF/STANDBY Encendido/Apagado/ReservaOperación básica continúa Luces indicadoras Panel frontalOtras funciones del UPS Panel posterior Operación básica continúa Almacenamiento ServicioProcedimiento SMX500RT1U SMX750RT1U SMX1000RT2U SMX1500XLRT2UManuel du propriétaire Systémes UPS intelligent, en attente activeMises en garde Connexions de lUPS Mises en garde Emplacement de lUPSDirectives de sécurité importantes Mises en garde Connexion déquipementMontage Bâti Bâti à quatre montantsMontage sur 2 montants Télécom Montage bâti suiteMontage Tour Tous les modèles dUPSFigure de la prise IEC320-C14 Connexion au port EPO tous les modèles Connexion de batterie externe modèles sélectBoutons Panneau avant Fonctionnement de base, suite Voyants indicateurs Panneau avantAutres caractéristiques de lUPS panneau arrière Fonctionnement de base, suite Service EntreposageProcédure Remarque sur étiquetageÐóêîâîäñòâî ïîëüçîâàòåëÿ Âàæíûå èíñòðóêöèè ïî òåõíèêå áåçîïàñíîñòè Ñîõðàíèòå ÝÒÈ ÈíñòðóêöèèÌîíòàæ Ñòîéêà Îïîðíûé ìîíòàæÂñå ìîäåëè ÓÏÑ Ìîíòàæ ñòîéêà, ïðîäîëæåíèåÌîíòàæ Áàøíÿ, ïèëîí Òîëüêî ìîäåëè ÓÏÑ 2UÏîäêëþ÷èòå âàøå îáîðóäîâàíèå ê ÓÏÑ Áûñòðàÿ óñòàíîâêàÂêëþ÷èòå ÓÏÑ Ñîåäèíåíèå ïîðòà 2 ÅÐÎ âñå ìîäåëè Äîïîëíèòåëüíûé ìîíòàæÏîðòû ïîñëåäîâàòåëüíîé ñâÿçè 1USB è RS-232 âñå ìîäåëè Ïîäêëþ÷åíèå âíåøíåãî àêêóìóëÿòîðà Îòäåëüíûå ìîäåëèÎñíîâíîé ðåæèì ðàáîòû Êíîïêè Ïåðåäíÿÿ ïàíåëüÎñíîâíîé ðåæèì ðàáîòû, ïðîäîëæåíèå Èíäèêàòîðíûå ëàìïî÷êè Ïåðåäíÿÿ ïàíåëüÄðóãèå âîçìîæíîñòè ÓÏÑ Çàäíÿÿ ïàíåëü Îñíîâíîé ðåæèì ðàáîòû, ïðîäîëæåíèå Õðàíåíèå Õðàíåíèå è îáñëóæèâàíèåÎáñëóæèâàíèå Çàìåíà àêêóìóëÿòîðà Òåõíè÷åñêèå õàðàêòåðèñòèêè
Related manuals
Manual 2 pages 41.47 Kb Manual 6 pages 46.05 Kb Manual 6 pages 50.23 Kb Manual 6 pages 48.8 Kb Manual 5 pages 41.56 Kb

SMX750RT1U, SMX1000RT2U, SMX1500XLRT2U, SMX3000XLRT2U, SMX500RT1U specifications

The Tripp Lite SMX500RT1U is a high-performance rack-mountable uninterruptible power supply (UPS) designed to protect critical equipment in server rooms and data centers. This compact unit provides reliable power backup and surge protection, ensuring that sensitive electronic devices remain operational during power outages or fluctuations.

One of the standout features of the SMX500RT1U is its 500VA/300W power capacity, which makes it suitable for protecting a variety of devices, including servers, network switches, and telecommunication equipment. The device offers sine wave output, which is essential for maintaining the integrity and reliability of powered equipment, particularly those with power-sensitive components.

The SMX500RT1U utilizes advanced battery technology, ensuring a dependable performance even under varying load conditions. Its internal batteries are designed for easy replacement, minimizing downtime and maintaining efficiency. The UPS also includes a smart charge technology, which optimizes charging time and extends battery life, ensuring that the unit is always ready to provide power when needed.

This model features six NEMA 5-15R output receptacles, allowing users to connect multiple devices while ensuring that they are protected from surges and brownouts. The unit also supports hot-swappable batteries, allowing for seamless battery replacement without interrupting the power supply to connected devices.

Another important characteristic of the SMX500RT1U is its versatility in management options. It comes equipped with USB and serial ports, enabling users to connect to their servers for monitoring and management. The included PowerAlert Software aids in providing detailed information on power conditions and allows for safe shutdowns in case of prolonged outages.

The Tripp Lite SMX500RT1U is designed with a form factor suitable for 1U rack installation, making it an excellent choice for space-constrained environments. Its efficient cooling design enhances performance while minimizing noise, making it ideal for use in any setting, from quieter network closets to bustling data centers.

In summary, the Tripp Lite SMX500RT1U is a robust UPS solution that offers essential features and technologies for users looking to protect their critical devices from power interruptions. Its reliable performance, ease of use, and compact design make it a valuable addition to any infrastructure in need of dependable power management.