Tripp Lite SMX1500XLRT2U Important Safety Instructions, UPS Location Warnings, Battery Warnings

Page 2

Important Safety Instructions

SAVE THESE INSTRUCTIONS

This manual contains important instructions that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty.

UPS Location Warnings

Use caution when lifting your UPS. Because of the considerable weight of all rackmount UPS systems, at least two people should assist in lifting and installing them.

Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight.

For best performance, the ambient temperature near your UPS should be between 0° C and 40° C (between 32° F and 104° F).

Leave adequate space around all sides of the UPS for proper ventilation. Do not obstruct its vents or fan openings.

UPS Connection Warnings

The UPS contains its own energy source (battery). The output terminals may be live even when the UPS is not connected to an AC supply.

Connect your UPS to a properly grounded AC power outlet. Do not modify the UPS’s plug in a way that would eliminate the UPS's connection to ground. Do not use adapters that eliminate the UPS’s connection to ground.

Do not plug your UPS into itself; this will damage the UPS and void your warranty.

If you are connecting your UPS to a motor-powered AC generator, the generator must provide filtered, frequency-regulated computer-grade output.

Equipment Connection Warnings

Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life-support device.

Do not connect surge suppressors or extension cords to the output of your UPS. This might overload the UPS and will void the surge suppressor and UPS warranties.

Battery Warnings

Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the UPS before performing battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery replacement should be performed only by authorized service personnel using the same number and type of batteries (sealed Lead-Acid). The batteries are recyclable. Refer to your local codes for disposal requirements or in the USA only call 1-800-SAV-LEAD or 1-800-8-BATTERY (1-800-8-228-8379) or visit www.rbrc.com for recycling information. Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.). Visit Tripp Lite on the Web at www.tripplite.com to locate the specific replacement battery for your UPS.

During hot-swap battery replacement, the UPS will not provide backup power in the event of a blackout or other power interruptions.

Do not operate UPS without batteries.

When adding external battery packs to select models with external battery pack connectors, connect only Tripp Lite-recommended battery packs of the correct voltage and type. Do not connect or disconnect battery packs when the UPS is operating on battery power.

2

Image 2
Contents Intelligent, Line-Interactive UPS Systems SMX500RT1U SMX750RT1U SMX1000RT2UUPS Location Warnings Important Safety InstructionsBattery Warnings UPS Connection WarningsMounting Rack Post MountingMounting Tower Post Telecom MountingTurn the UPS on External Battery Connection select models Buttons Front Panel Indicator Lights Front Panel Other UPS Features Rear Panel Basic Operation Service StorageProcedure OutputManual del propietario Sistemas de UPS Inteligentes e Interactivos en LíneaAdvertencias sobre la conexión del UPS Instrucciones de seguridad importantesAdvertencias sobre la ubicación del UPS Advertencias sobre la conexión de equiposMontaje Bastidor Montaje de 4 postesMontaje de 2 postes Telecomunicaciones Montaje en bastidor continúaMontaje En torre Tolos los modelos de UPSEn el enchufe de toma eléctrica C.A Encienda el UPSConexión de batería externa modelos exclusivos Comunicaciones USB y serie RS-232 todos los modelosConexión de puerto EPO todos los modelos Botones Panel frontal Botón ON/OFF/STANDBY Encendido/Apagado/ReservaOperación básica continúa Luces indicadoras Panel frontalOtras funciones del UPS Panel posterior Operación básica continúa Almacenamiento ServicioProcedimiento SMX500RT1U SMX750RT1U SMX1000RT2U SMX1500XLRT2UManuel du propriétaire Systémes UPS intelligent, en attente activeMises en garde Connexions de lUPS Mises en garde Emplacement de lUPSDirectives de sécurité importantes Mises en garde Connexion déquipementMontage Bâti Bâti à quatre montantsMontage sur 2 montants Télécom Montage bâti suiteMontage Tour Tous les modèles dUPSFigure de la prise IEC320-C14 Connexion au port EPO tous les modèles Connexion de batterie externe modèles sélectBoutons Panneau avant Fonctionnement de base, suite Voyants indicateurs Panneau avantAutres caractéristiques de lUPS panneau arrière Fonctionnement de base, suite Service EntreposageProcédure Remarque sur étiquetageÐóêîâîäñòâî ïîëüçîâàòåëÿ Âàæíûå èíñòðóêöèè ïî òåõíèêå áåçîïàñíîñòè Ñîõðàíèòå ÝÒÈ ÈíñòðóêöèèÌîíòàæ Ñòîéêà Îïîðíûé ìîíòàæÂñå ìîäåëè ÓÏÑ Ìîíòàæ ñòîéêà, ïðîäîëæåíèåÌîíòàæ Áàøíÿ, ïèëîí Òîëüêî ìîäåëè ÓÏÑ 2UÂêëþ÷èòå ÓÏÑ Áûñòðàÿ óñòàíîâêàÏîäêëþ÷èòå âàøå îáîðóäîâàíèå ê ÓÏÑ Ñîåäèíåíèå ïîðòà 2 ÅÐÎ âñå ìîäåëè Äîïîëíèòåëüíûé ìîíòàæÏîðòû ïîñëåäîâàòåëüíîé ñâÿçè 1USB è RS-232 âñå ìîäåëè Ïîäêëþ÷åíèå âíåøíåãî àêêóìóëÿòîðà Îòäåëüíûå ìîäåëèÎñíîâíîé ðåæèì ðàáîòû Êíîïêè Ïåðåäíÿÿ ïàíåëüÎñíîâíîé ðåæèì ðàáîòû, ïðîäîëæåíèå Èíäèêàòîðíûå ëàìïî÷êè Ïåðåäíÿÿ ïàíåëüÄðóãèå âîçìîæíîñòè ÓÏÑ Çàäíÿÿ ïàíåëü Îñíîâíîé ðåæèì ðàáîòû, ïðîäîëæåíèå Îáñëóæèâàíèå Õðàíåíèå è îáñëóæèâàíèåÕðàíåíèå Çàìåíà àêêóìóëÿòîðà Òåõíè÷åñêèå õàðàêòåðèñòèêè
Related manuals
Manual 2 pages 41.47 Kb Manual 6 pages 46.05 Kb Manual 6 pages 50.23 Kb Manual 6 pages 48.8 Kb Manual 5 pages 41.56 Kb

SMX750RT1U, SMX1000RT2U, SMX1500XLRT2U, SMX3000XLRT2U, SMX500RT1U specifications

The Tripp Lite SMX500RT1U is a high-performance rack-mountable uninterruptible power supply (UPS) designed to protect critical equipment in server rooms and data centers. This compact unit provides reliable power backup and surge protection, ensuring that sensitive electronic devices remain operational during power outages or fluctuations.

One of the standout features of the SMX500RT1U is its 500VA/300W power capacity, which makes it suitable for protecting a variety of devices, including servers, network switches, and telecommunication equipment. The device offers sine wave output, which is essential for maintaining the integrity and reliability of powered equipment, particularly those with power-sensitive components.

The SMX500RT1U utilizes advanced battery technology, ensuring a dependable performance even under varying load conditions. Its internal batteries are designed for easy replacement, minimizing downtime and maintaining efficiency. The UPS also includes a smart charge technology, which optimizes charging time and extends battery life, ensuring that the unit is always ready to provide power when needed.

This model features six NEMA 5-15R output receptacles, allowing users to connect multiple devices while ensuring that they are protected from surges and brownouts. The unit also supports hot-swappable batteries, allowing for seamless battery replacement without interrupting the power supply to connected devices.

Another important characteristic of the SMX500RT1U is its versatility in management options. It comes equipped with USB and serial ports, enabling users to connect to their servers for monitoring and management. The included PowerAlert Software aids in providing detailed information on power conditions and allows for safe shutdowns in case of prolonged outages.

The Tripp Lite SMX500RT1U is designed with a form factor suitable for 1U rack installation, making it an excellent choice for space-constrained environments. Its efficient cooling design enhances performance while minimizing noise, making it ideal for use in any setting, from quieter network closets to bustling data centers.

In summary, the Tripp Lite SMX500RT1U is a robust UPS solution that offers essential features and technologies for users looking to protect their critical devices from power interruptions. Its reliable performance, ease of use, and compact design make it a valuable addition to any infrastructure in need of dependable power management.