Specifications
| MODEL NUMBER: | EMS1012UL | EMS1250UL | EMS2012UL |
| Series Number: | AGAP100012MV3 | AGAP5094 | AGAP200012MV3 |
|
|
|
|
|
| AC Input Connection: | Input Cord | Input Cord | Hardwire |
|
|
|
|
|
| INVERTER |
|
|
|
|
|
|
|
|
| Common Specifications for All Models • DC Input Volts (Nominal): 12 VDC • DC Input Voltage Range: 10 - 15 VDC | • Output Volts (Nominal): 120 VAC, ± 5% | • Output Frequency (Nominal): 60 Hz, ± 0.5% | |
| • Efficiency: 88% to 94% depending on load and temperature |
|
|
|
Tripp Lite Inverter/Chargers include a Battery Charge Conserver (Load Sense) Control which saves battery power by allowing users to set the minimum load level at which the unit’s inverter turns on. Users can significantly reduce the No Load DC Input Current (approximately 1 A to 3 A for all models) to a very low amp level with the use of this control.
| Continuous Power (@ 20 C): | 1000 | 1250 | 2000 |
| OverPower™ Peak Surge Power:* | 1500 | 1875 | 3000 |
|
|
|
|
|
| Double Boost™ Peak Surge Power:* | 2000 | 2500 | 4000 |
|
|
|
|
|
| Maximum Output AC Current (Continuous): | 8.3 A | 10.4 A | 16.7 A |
|
|
|
|
|
| 200 A | 200 A | 400 A | |
|
|
|
|
|
| DC Input Current @ Nominal V DC |
|
|
|
| Full Load | 95 A | 127 A | 190 A |
|
|
|
|
|
| BATTERY CHARGER |
|
|
|
|
|
|
|
|
| Common Specifications for All Models • Acceptance Volts VDC: Selectable 14.4 V** / 14.2 V Wet** / Gel | • Float Volts DC (w/gel): 13.3 V (13.6 V) | • Input Volts (Nominal): 120 VAC | |
| Charging Capacity DC: | 55 A**/14 A | 55 A** / 14 A | 100 A**/25 A |
|
|
|
|
|
| Input Current AC: | 11.5 A | 11 A | 20A |
LINE VAC OPERATION
| Common Specifications for All Models • Minimum Input Volts (Transfer to Battery): Selectable 75,** 85, 95 or 105 VAC | • Maximum Input Volts (Transfer to Battery): Selectable 135** or 145 VAC † • Input | ||
| Frequency (Nominal): 60 Hz, ±10% |
|
|
|
|
|
|
|
|
| Maximum Input AC Current (Continuous, Charger at Maximum): | 12 A | 12 A | 38 A |
|
|
|
|
|
| Maximum Bypass AC Current (load circuit breaker limited): | 12 A | 12 A | 20 A |
*OverPower duration (up to 1 hour). DoubleBoost duration (up to 10 seconds). Actual duration depends on battery age, battery charge level and ambient temperature. **Factory setting. † Not applicable to Model EMS1250UL; switches select Charger Enable/Charger Inhibit. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
Minimum Recommended Cable Sizing Chart*
Use in conjunction with DC wiring connection instructions in the Battery Connection section.
|
| Inverter/Charger DC Volt: 12 |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| Wire Gauge |
|
| ||
|
|
|
|
|
|
|
|
|
| Watts | 6 | 4 |
| 2 |
| 0 | 00 (2/0) |
| 500 | 15 ft | 25 ft |
| 39 ft |
| 62 ft | 79 ft |
| 700 | 11 ft | 18 ft |
| 28 ft |
| 44 ft | 56 ft |
| 1000 | N/R | 12 ft |
| 20 ft |
| 31 ft | 39 ft |
2000 | N/R | N/R |
| N/R |
| 16 ft | 20 ft | |
|
|
|
|
|
|
|
|
|
| 2400 | N/R | N/R |
| N/R |
| 13 ft | 16 ft |
| 3000 | N/R | N/R |
| N/R |
| 10 ft | 13 ft |
* N/R = Not Recommended. NOTE: Acceptable power is directly related to cable length (i.e. the shorter the cable, the better the performance)
Note on Labeling Two symbols are used on the EMS labels. V~: AC Voltage V : DC Voltage
200412021