Tripp Lite 725 owner manual Indicator Lights, Other UPS Features

Page 5

Indicator Lights

All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned on.

This green light will turn ON whenever your UPS is plugged in and receiving normal AC line power.

This red light will turn ON when your UPS is providing your equipment with battery power.

This yellow light will turn ON continuously after you test your UPS battery’s charge with the “MUTE/TEST” Switch if the UPS’s battery is less than fully charged. If it stays on continuously, contact Tripp Lite for service. The light will flash after you set the “OFF/ON” Switch to the “OFF” position to indicate that the UPS will not provide battery backup during a blackout or brownout.

Whenever your UPS is automatically correcting high or low AC line voltage, this green light will turn ON and the UPS will gently click. The more the UPS has to correct voltage, the more the green light will turn ON and the more the UPS will click. These are both normal, automatic operations of your UPS, and no action is required on your part.

Other UPS Features

AC Receptacles

The “battery supported” receptacles on your UPS provide your connected equipment with AC line power during normal opera- tion and with battery power during blackouts and brownouts. They also protect your equipment against damaging surges and line noise. The “surge-only” receptacles provide peripherals with surge protection without committing precious battery power to support them during blackouts.

RJ11 Telephone Jacks

These jacks protect your equipment against telephone line surges. Connecting your equipment to these jacks is optional. Your UPS will still work properly without this connection.

DB9 Port

The DB9 port connects your UPS to any workstation or server. Use with Tripp Lite software and cabling to automatically save open files and shut down equipment during a blackout. This port sends contact-closure signals to indicate line-fail and low- battery status. Contact Tripp Lite Customer Support for more information.

Battery Replacement Door

Under normal conditions, the original battery in your UPS will last several years. Battery replacement should be performed only by qualified service personnel. Refer to “Battery Warnings” in the Safety section on page 2.

5

Image 5
Contents Quick Installation Battery Warnings Safety UPS Location Warnings UPS Connection WarningsOptional Installation† Quick InstallationSwitch Silence the UPS On-Battery alarm SwitchesTest your UPSs battery charge Basic OperationOther UPS Features Indicator LightsSpecifications Storage & ServiceService StorageInstalación Rápida Advertencias Sobre la Instalación SeguridadAdvertencias Sobre la Conexión Advertencias Sobre la Conexión de EquiposInstalación Rápida Operación Básica Silenciar de la alarma de apagonesInterruptores Posición on encendidoArrancar en frío el no-break / sistema UPS Luces IndicadorasReceptáculos de CA Otras Características de este No-break / Sistema UPSContactos Telefónicos Tipo RJ11 Puerto DB9Especificaciones Almacenaje y ServicioAlmacenaje ServicioInstallation Rapide Recommandations Relatives à la Connexion de lUPS Recommandations Relatives à l’Emplacement de lUPSRecommandations relatives à la Connexion du Matériel Recommandations relatives à la BatterieInstallation Facultative -† Installation RapideOpération de Base Amortir l’alarme du système d’UPSCommutateurs Tester la charge de la batterie de votre système d’UPSRéceptacles C.A Voyants de SignalisationAutres Dispositifs d’UPS Porte de Remplacement de la Batterie Entreposage & ServiceEntreposage Prises Jacks de téléphone RJ11Protection Modem/Fax Commence à Lignes Caractéristiques