Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains important instructions that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty.
UPS Location Warnings
Mounting
Mount your equipment in either a
•Use caution when lifting your UPS. Because of the considerable weight of all rackmount UPS systems, at least two people should assist in lifting and installing them.
•Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight.
•For best performance, the ambient temperature near your UPS should be between 0° C and 40° C (between 32° F and 104° F).
•Leave adequate space around all sides of the UPS for proper ventilation. Do not obstruct its vents or fan openings.
UPS Connection Warnings
•The UPS contains its own energy source (battery). The output terminals may be live even when the UPS is not connected to an AC supply.
4-Post Rack Mounting
1 Loosen the wingnuts A on each of the two adjustable |
side supports B ; adjust the length of the supports to |
match the depth of your rack; tighten wingnuts. Mount |
both side supports in the lowest space of your rack on |
the inside surfaces of the rails with |
32 rack bolts and washers C . Note: Both support |
ledges should face inward. The side supports’ front |
and back holes are threaded and do not require nuts to |
CC |
1
B |
B |
CC |
A |
A |
Equipment Connection Warnings
•Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a
•Do not connect surge suppressors or extension cords to the output of your UPS. This might overload the UPS and will void the surge suppressor and UPS warranties.
Battery Warnings
• Batteries can present a risk of electrical shock and burn from high |
Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or |
batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the |
UPS before performing battery replacement. Use tools with insulated handles. There are no |
authorized service personnel using the same number and type of batteries (sealed |
The batteries are recyclable. Refer to your local codes for disposal requirements. Tripp Lite |
offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.). Visit Tripp |
secure rack bolts. |
2 Attach mounting ears D to the front mounting holes |
of your UPS E using the screws provided F . The |
ears should face forward. |
3Using an assistant if necessary, lift your UPS and slide it onto the mounting shelves (if your model includes the shelves). Attach your UPS to the rack by using the appropriate hardware G through its mounting ears and into the rack rails.
E
D | F |
2 |
|
G |
|
3 |
|
Lite on the Web at www.tripplite.com to locate the specific replacement battery for your UPS. |
• During |
a blackout or other power interruptions. |
• Do not operate UPS without batteries. |
• When adding external battery packs connect only Tripp |
the correct voltage and type. Do not connect or disconnect battery packs when the UPS is |
operating on battery power. |
2
2-Post Rack (Telecom) Mounting
If you mount 3U UPS models in
Tower Mounting
If you tower mount this UPS, it requires the addition of a Tripp Lite 2U to 9U tower stand (model:
Rotate the power module’s Control Panel to view it easier while the UPS is tower mounted. Insert a small screwdriver, or other tool, in the slots on either side of the Control Panel. Pop the panel out; rotate it; and pop the panel back into place.
3