Storage and Service

Storage

Before storing your UPS, place it in the OFF mode by putting it in STANDBY, then unplugging it (See Basic Operation). If you store your UPS for an extended period of time, recharge the UPS batteries once every three months by following Step 1 in the Connection section and allowing the UPS to charge for 4-6 hours before placing it back in storage. If you leave your UPS batteries discharged for an extended period of time, they will suffer a permanent loss of capacity.

Service

If returning your UPS for service, contact your local Tripp Lite dealer or distributor. They will refer you to a service center. Please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit. Enclose a letter describing the symptoms of the problem. If the UPS is within the 2 year warranty period, enclose a copy of your sales receipt.

Battery Replacement

Under normal conditions, the original batteries in your UPS will last many years. Battery replacement should be performed only by qualified service personnel. Refer to “Battery Warnings” in the Safety section. When replacing the batteries, qualified service personnel should use the following procedure. The UPS is designed for hot swap battery replacement, but to reduce the risk of exposure to potentially dangerous high voltages the UPS may be put in the OFF mode before battery replacement.

A

1.Make sure your UPS is not in INVERT mode, i.e. that the “ + – ” light is NOT flashing.

2.Remove the front panel by unscrewing the four screws in its corners. Allow it to dangle by the ribbon cable connecting the controls and LEDs to the UPS.

3.Slide the internal battery cartridges partially out of the UPS towards the front until their electrical connection (A) may be disconnected.

4.Remove batteries from the UPS completely and dispose of them properly. Refer to “Battery Warnings” in the Safety section for recycling and disposal information.

5.Connect replacement batteries, making sure that the input and output cables (A) are connected as before, according to the colors in the diagram. Reassemble the UPS by reversing the steps above. Note: your new batteries should be allowed to charge for 2-4 hours before they support a load.

10

Image 10
Contents SmartPro 1U Rackmount UPS Location Warnings Important Safety InstructionsBattery Warnings UPS Connection WarningsRackmount Matching Your Front Panel to Your EquipmentDesktop/Under-Monitor Plug your equipment into Your UPS Plug your UPS into an Electrical outletTurn your UPS on USB Port Connection Connection optionalSerial Port Connection EPO Port ConnectionButtons Front Panel Indicator Lights Front Panel Other UPS Features Rear Panel AC ReceptaclesInput Breaker Service StorageSMART750RM1U SMART1000RM1U Page Manual del propietario Advertencias sobre la conexión del UPS Instrucciones de seguridad importantesAdvertencias sobre la ubicación del UPS Advertencias sobre la conexión de equiposMontaje en rack bastidor Color del panel frontal en juego con sus equiposSobre el escritorio o debajo del monitor Conecte sus equipos con el UPS Conecte su UPS en un TomacorrienteEncienda su UPS on Conexión con puerto USB Conexión opcionalConexión con puerto serie Conexión de puerto EPOBotones Panel frontal Operación básica continúa Luces indicadoras Panel frontalOtras funciones del UPS Panel posterior Norm Delay Almacenamiento ServicioModelo 200210187