Tripp Lite 1000 VA owner manual SMART750RM1U SMART1000RM1U

Page 11

200210187 Smart 700-1000 RM1U Owner’s Manual 93-2102.qxd 11/1/2002 9:50 AM Page 11

Specifications

Model:

SMART750RM1U

SMART1000RM1U

Series:

AGSM1000Y1U31

AGSM1000Y1U31

Output Capacity (VA/Watts):

750/450

1000/700

Battery Runtime in Minutes

 

 

(Half Load/Full Load):

18/7

13/5

Battery Recharge Time:

2-4 hrs.

2-4 hrs.

Approvals:

UL, cUL, NOM

UL, cUL, NOM

All Models: Input Voltage (120V); Input Frequency (60 Hz); On-Battery Output Voltage Range (115V ± 8%); Output Waveform Line Mode (filtered sinewave); Output Waveform Battery Mode (sine wave); AC Surge Suppression (meets IEEE 587 Cat. A & B standards); AC Noise Attenuation (>40 dB); AC Protection Modes (H to N, H to G, N to G).

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

11

Image 11
Contents SmartPro 1U Rackmount UPS Connection Warnings Important Safety InstructionsBattery Warnings UPS Location WarningsDesktop/Under-Monitor Matching Your Front Panel to Your EquipmentRackmount Turn your UPS on Plug your UPS into an Electrical outletPlug your equipment into Your UPS EPO Port Connection Connection optionalSerial Port Connection USB Port ConnectionButtons Front Panel Indicator Lights Front Panel AC Receptacles Other UPS Features Rear PanelInput Breaker Storage ServiceSMART750RM1U SMART1000RM1U Page Manual del propietario Advertencias sobre la conexión de equipos Instrucciones de seguridad importantesAdvertencias sobre la ubicación del UPS Advertencias sobre la conexión del UPSSobre el escritorio o debajo del monitor Color del panel frontal en juego con sus equiposMontaje en rack bastidor Encienda su UPS on Conecte su UPS en un TomacorrienteConecte sus equipos con el UPS Conexión de puerto EPO Conexión opcionalConexión con puerto serie Conexión con puerto USBBotones Panel frontal Luces indicadoras Panel frontal Operación básica continúaOtras funciones del UPS Panel posterior Norm Delay Servicio AlmacenamientoModelo 200210187