Basic Operation continued

Indicator Lights (Front Panel)

All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned ON.

+ –

POWER: Lights green when the UPS is receiving AC power. Illuminates constantly when the UPS is in the ON mode, indicating that batteries are charging and connected equipment is receiving filtered AC power. Flashes while in STANDBY mode to indicate that batteries are charging but connected equipment is not receiving power.

BATTERY CHARGE: This multicolored light displays 6 separate UPS battery charge conditions. It will turn from red (low) to yellow (medium) to green (full) to show you the level of battery charge. If the light is constant, your UPS is in the ON or STANDBY mode, operating from line power, and the battery is charging. Whenever this light is flashing, your UPS is in the INVERT mode (operating from battery) and its battery is discharging. If the light is flashing red, your UPS battery is running out of power; you should save files and shut down your equipment immediately.

OUTPUT LOAD: This multicolored light shows how heavy your UPS’s load is. Steady green indicates a light load, steady yellow a medium load. When the light is red, your UPS is supporting a load above 85% of its capacity. If the red light begins flashing, then your inverter is severely overloaded. Immediately remove load from the UPS until the light stops flashing.

+

REPLACE BATTERY: Lights red if your UPS’s self-test (initiated with the MUTE/TEST Switch) reveals a low battery charge or internal fault. If this light turns on, let the UPS charge for 12 hours then perform a second self-test. If the light stays on, contact Tripp Lite for service.

7

Image 7
Contents SmartPro 1U Rackmount UPS Connection Warnings Important Safety InstructionsBattery Warnings UPS Location WarningsRackmount Matching Your Front Panel to Your EquipmentDesktop/Under-Monitor Plug your equipment into Your UPS Plug your UPS into an Electrical outletTurn your UPS on EPO Port Connection Connection optionalSerial Port Connection USB Port ConnectionButtons Front Panel Indicator Lights Front Panel AC Receptacles Other UPS Features Rear PanelInput Breaker Storage ServiceSMART750RM1U SMART1000RM1U Page Manual del propietario Advertencias sobre la conexión de equipos Instrucciones de seguridad importantesAdvertencias sobre la ubicación del UPS Advertencias sobre la conexión del UPSMontaje en rack bastidor Color del panel frontal en juego con sus equiposSobre el escritorio o debajo del monitor Conecte sus equipos con el UPS Conecte su UPS en un TomacorrienteEncienda su UPS on Conexión de puerto EPO Conexión opcionalConexión con puerto serie Conexión con puerto USBBotones Panel frontal Luces indicadoras Panel frontal Operación básica continúaOtras funciones del UPS Panel posterior Norm Delay Servicio AlmacenamientoModelo 200210187