Tripp Lite PDUMNV20 owner manual Accy Port The port is reserved for future expansion

Page 9

Features continued

Circuit Breakers (Select Models): If the connected equipment load on a load bank exceeds the Maximum Load Rating of the load bank, the circuit breaker will trip. Disconnect excess equipment and switch breaker to the on position to reset the breaker. Models with multiple outlet banks have a circuit breaker for each bank. Circuit breakers are only used to protect output load banks.

Cord Retention Bracket: Provides secure attachment points for connected equipment cords.

Mounting Brackets: Use these brackets to mount the PDU.

A

LINK

 

 

 

STATUS

 

 

 

 

 

 

RESET

CONFIG

OSENSE

ACCY

VIR

 

EN

 

PDUMVROTATEBRKT Mounting Accessory: Use these V-shaped brackets to mount the PDU with its outlets facing the rear of the rack.

SNMP Reset Button: Press the reset button A for 3 seconds to reboot the PDU's network card. Rebooting the network card will not erase network settings or interrupt AC power. The reset button is recessed; use a suitable tool to press it.

ACCY Port: The port is reserved for future expansion.

PS/2 Port: Use this port to connect a Tripp Lite ENVIROSENSE environmental sensor to provide remote temperature/humidity monitoring and a dry contact interface to control and monitor alarm, security and telecom devices. Visit www.tripplite.com for ordering information. Note: Do not connect a keyboard or mouse to this port.

RJ-45 Configuration Port: Use this port to provide a direct terminal connection to a computer with a terminal emulation program. An RJ-45 cable is included with the PDU. If you need a replacement cable, visit www.tripplite.com for ordering information.

9

201112142 933151.indb 9

1/24/2012 2:09:59 PM

Image 9
Contents Monitored Rack PDU Important Safety Instructions Monitored Rack PDU FeaturesSwitched Rack PDU Features Mounting the PDU InstallationPower cord connection Connecting the PDUNetworking the PDU Dynamic IP Address AssignmentStatic IP Address Assignment None Network Interface Parameters Testing Network ConnectionIEC 309 3-Pole Input Plug Available on select models FeaturesAccy Port The port is reserved for future expansion Remote Monitoring and Control Configuration and OperationLimited Warranty Warranty and Warranty Registration201112142 933151-EN Manual del propietario Instrucciones de seguridad importantes Características de la PDU Monitoreada para RackCaracterísticas alternas de la PDU para Rack Montaje del PDU InstalaciónConexión del PDU Instalación continuaciónConectando Su PDU a la Red Asignación de una Dirección IP DinámicaAsignación de una Dirección IP Estática 5Configure el PDU en Modo Terminal Probando la Conexión de Red Características Los modelos de 20-amp presentan un Interruptor para Características continuaciónPower over Ethernet / Energía sobre la Ethernet Control y monitoreo remoto Configuración y operaciónGarantía Limitada GarantíaManuel du propriétaire Caractéristiques de la PDU en bâti surveillée Importantes consignes de sécuritéMontage de lunité de distribution dalimentation PDU Caractéristiques de la PDU en bâti à liaison commutéeConnexion de lunité de distribution dalimentation PDU Installation suiteMise en réseau de lunité de distribution Affectation dune adresse IP dynamiqueAffectation dune adresse IP statique 3Connecter la PDU à lordinateur Test de la connexion réseau Caractéristiques Caractéristiques suite PoE Power Over Ethernet Surveillance et commande à distance Configuration et fonctionnementGarantie Limitée Garantie