NTI SERIMUX SERIES CONSOLE SWITCH
From the Port settings menu, the configuration of each port can be viewed and changed.
Setting | Description |
| Value | ||
Port name | Change the port name |
| Max. 15 characters | ||
Port type | Host or User |
| H | or U | |
Select characters to use for in- |
| 1 + code for | |||
sequence | band disconnect sequence |
| 3 + desired characters for | ||
|
|
| 0- for no disconnect sequence | ||
|
|
| T- | display Control code list | |
Connection | Time left before connection will be |
| |||
Timeout | broken due to receiver inactivity |
| never timeout. | ||
Serial settings | Display serial settings menu |
| N/a | ||
Modem settings | Display modem settings menu |
| N/a | ||
View port data | View the last 1016 characters |
| N/a |
| |
buffer | received and transmitted to/from |
|
|
|
|
| the port |
|
|
|
|
VT100 displaying | Modify the displaying extra delay |
| 0 = None,1 = normal, 2 = double, or 3 = triple |
| |
delay |
|
| "None" value can be used if the display is faster (i.e. with a |
| |
|
|
|
| ||
|
|
| terminal emulator, like HyperTerminal, running on a PC); the |
| |
|
|
| other values are useful if real terminals or slower serial |
| |
|
|
| devices are used as user/administrator consoles. |
| |
Reset Port settings | Restores factory default port |
| A confirmation "Y" will be required |
| |
to default | settings |
|
|
|
|
When [3] is pressed to change the
Note: If the
FYI: If the
Figure 7- Control Codes for in-band disconnect sequence
- | When selecting each new port setting values, press [Esc] or [Spacebar] to cancel, or press [Enter] to save. |
-Press [>] (greater than symbol) to display the current settings for the next port.
-Press [<] (less than symbol) to display the current settings for the previous port
-Press [Esc] or [Spacebar] to return to the "Administrator main menu"
10