NTI SERIMUX SERIES CONSOLE SWITCH

Appendix A - SERIMUX Port Characteristics

Every port is defined through the following parameters:

 

Description

 

 

Acceptable Value

 

 

Default Value

 

 

 

 

 

 

 

 

Number

0-8/16/24/32

 

Same (not changeable)

 

Name

 

Up to 15 characters

 

 

“Port00” to “Port32”

 

Type – port 0

 

User

 

 

User (not changeable)

 

Type – except port 0

 

User or Host

 

 

Host

 

Baud rate – port 0

300-115200

 

9600

 

 

Baud rate – except port 0

50-128000

 

9600

 

 

Data bits per character – port 0

7,8

 

8

 

 

Data bits per character – except port 0

5,6,7,8

 

8

 

 

Stop bits – port 0

1, 2

 

1

 

 

Stop bits – except port 0

1, 1-1/2, 2, 2-1/2

 

1

 

 

Parity

No parity, even, odd

 

 

No parity

 

Handshake mode (flow control)

 

Xon / Xoff (or in-band, or software),

 

None

 

 

 

 

RTS/CTS (or out-band or hardware),

 

 

 

 

 

 

 

Both,

 

 

 

 

 

 

 

 

None

 

 

 

 

 

Xon character

 

any ASCII nonprintable character

(0-31 range)

 

Ctrl+Q (17)

 

Xoff character

any ASCII nonprintable character

(0-31 range)

 

Ctrl+S (19)

 

Inter-character delay – except port 0

 

1-60 milliseconds, none

 

 

None

 

(no delay allowed on port 0)

 

 

 

 

 

 

 

Line break receive allowance – except port 0

 

Yes or No

 

 

No

 

(no allowance for port 0)

 

 

 

 

 

 

 

Transmitted line break extra duration (added

 

No break transmitted, 1-999 milliseconds

 

No break transmitted

 

to 1 character transmission time) – except

 

 

 

 

 

 

 

port 0 (no extra duration for port 0)

 

 

 

 

 

 

 

In-band disconnect sequence

 

0 (disabled), 1, or 3 characters sequence

 

1-char sequence

 

 

 

 

 

 

 

1 character disconnect sequence

 

Any ASCII nonprintable character (0-31 range)

 

Ctrl+X (24)

 

3 character disconnect sequence

 

Any 3 ASCII characters

 

 

``` (3 back quotes)

 

Connection timeout

 

1-90 minutes, never

 

 

15 minutes

 

DTR output upon disconnect

 

Low, high, or pulsed for 0.5 seconds and then held

 

High

 

 

 

 

high

 

 

 

 

 

Modem Reset string

 

Up to 41 characters

 

 

ATZ

 

Modem Initialization string

 

Up to 41 characters

 

 

AT&F&C1&D2S0=0

 

Modem Disconnect string

 

Up to 41 characters

 

 

ATH

Appendix B - SERIMUX User and Administrator Characteristics

The users and the administrator are defined through the following parameters:

Description

Acceptable Value

Default Value

Users:

 

 

User number

1 to 32

Same (not changeable)

User name

Up to 15 characters – case sensitive

“User01” to “User32”

User password

Up to 31 characters – case sensitive

“” (empty string)

User enabled

Yes or No

Not enabled, except

 

 

User 1: enabled

Administrative privileges

Yes or No

No

Access to ports

Port 0 always; Ports 1-31

Port 0, except

 

 

User 1: all ports

User menu timeout

1-90 minutes, never

15 minutes

Administrator:

 

 

Administrator name

“ADMINISTRATOR” or “ROOT” – case sensitive

Same (not changeable)

Administrator password

Up to 31 characters – case sensitive

“NTI”

Administrator menu timeout

1-90 minutes, never

15 minutes

User to auto login

User 1-32, None

User 1

31

Image 35
Contents Console Switch Trademark Table of Contents Table of Figures Materials Supplied with this kit Also supplied with units having RJ45 connectorsIntroduction MaterialsDefinitions Serial Interface SpecificationsRear View of Serimux Features and FunctionsCable Connections InstallationRJ45 Male Connector Rack mounting InstructionsSerimux Quick Start Initial StartupSerial Control Using the Serimux Console SwitchSerial Control Root all capital lettersLogin as the administrator Administrator ControlsPort list displays the status of all ports Port ListPort settings menu Port SettingsSetting Description Value Port serial settings DTR line behavior Inter-character delayFlow control Command Xon or Xoff CharactersDisplay serial settings for different port number Modem settingsCopy Port Serial Settings Port data buffer Display modem settings for different port numberUser List User ListUser settings menu User SettingsCopy User Settings Port accessChange administrator password Advanced SettingsLoad new firmware Save current firmware FirmwareUser Controls User Accessible host list screenUser main menu User with limited host port accessPort List screen Limited user accessible Port list¾ Connect to port User Terse modeTerse mode commands ¾ Accessible host listFunctions of the Keypad ¾ Verbose mode¾ Login the administrator Keypad Control¾ Login user to a port ¾ Login a user to the administrator main menuAction from Keypad ¾ Disconnect and logout a user¾ Connect 2 host ports To detach a modem Initialize Serimux Console Switch to default settingsUsing the Keypad ¾ Attach or detach a modemUsing The Reset Button Firmware UpgradeNew firmware upload window Troubleshooting Interconnection Cable Wiring MethodUsers Appendix a Serimux Port CharacteristicsAppendix B Serimux User and Administrator Characteristics AdministratorAppendix C- Cable Adapters RJ45 Signal DB-25MRJ45 Signal RJ45 Signal DB-25F Ethernet Pinouts SpecificationsWarranty Information Index