Network Technologies Console Switch Advanced Settings, Change administrator password

Page 22

NTI SERIMUX SERIES CONSOLE SWITCH

Advanced Settings

From the "Administrator main menu", press [7] to display the “Advanced settings” menu.

 

Figure 14- Administrator's Advanced settings menu

From the "Advanced settings" menu the administrator can perform the following functions:

 

 

 

Setting

Description

Value

Administrator

Define the password to be used by the

Max. 31 characters.

Password

administrator

This can only be changed if old password is known.

 

 

(If SERIMUX is re-initialized, the password will change back

 

 

to 'NTI")

Administrator

the time interval of administrator inactivity,

0-90 minutes 0 = Never

Timeout

prior to logging out.

 

Unit name

Name assigned to the SERIMUX

Max. 40 characters

User to auto login

User assigned to automatically login at

Index number of any enabled user that has access to the port

 

power up without a password.

being used for the user port

 

 

 

Connect two host

Connect two host ports together

Enter host port index number, press [Enter], second host port

ports

 

index number, and press [Enter] again

Firmware

Display the firmware menu

See pg. 19

FYI: If at powerup the auto-login user does not have access to port being used, a login by a valid user with access rights will be required.

Change administrator password

For security purposes the administrator should change the factory default administrator password to a unique password. This will prevent unauthorized access to switch functions and CPUs. The password is needed to log in from any device, connected to any SERIMUX port in buffer mode.

To change the administrator password, from the Administrator main menu;

-press [7] to choose Advanced settings and press [Enter]. The Advanced settings menu will appear (Fig. 14)

-press [1] and a prompt for the old password will appear

-enter the old password (factory default password is "NTI") and press [Enter]

-enter a new password (maximum 31 ASCII characters), using the [Backspace] key to erase any characters entered

in error, and press [Enter]

-re-enter the password to confirm it, and press [Enter]

-a message "OK" will appear, press any key to return to the Advanced settings menu

NOTE: The password entered will be case sensitive so be sure to note what characters are used and what case they are in if any are alphabetical. The password characters are displayed as ‘*’ (asterisk) characters while entering them.

NOTE: If the administrator password is not known, the administrator must re-initialize the SERIMUX following the "Initialize SERIMUX Console Switch to default settings" instructions on page 27.

18

Image 22
Contents Console Switch Trademark Table of Contents Table of Figures Materials Also supplied with units having RJ45 connectorsIntroduction Materials Supplied with this kitSerial Interface Specifications DefinitionsFeatures and Functions Rear View of SerimuxRack mounting Instructions InstallationRJ45 Male Connector Cable ConnectionsInitial Startup Serimux Quick StartRoot all capital letters Using the Serimux Console SwitchSerial Control Serial ControlAdministrator Controls Login as the administratorPort List Port list displays the status of all portsPort Settings Port settings menuSetting Description Value Port serial settings Xon or Xoff Characters Inter-character delayFlow control Command DTR line behaviorCopy Port Serial Settings Modem settingsDisplay serial settings for different port number Display modem settings for different port number Port data bufferUser List User ListUser Settings User settings menuPort access Copy User SettingsAdvanced Settings Change administrator passwordFirmware Load new firmware Save current firmwareUser Accessible host list screen User ControlsUser with limited host port access User main menuLimited user accessible Port list Port List screen¾ Accessible host list User Terse modeTerse mode commands ¾ Connect to portKeypad Control ¾ Verbose mode¾ Login the administrator Functions of the Keypad¾ Login a user to the administrator main menu ¾ Login user to a port¾ Connect 2 host ports ¾ Disconnect and logout a userAction from Keypad ¾ Attach or detach a modem Initialize Serimux Console Switch to default settingsUsing the Keypad To detach a modemFirmware Upgrade Using The Reset ButtonNew firmware upload window Interconnection Cable Wiring Method TroubleshootingAdministrator Appendix a Serimux Port CharacteristicsAppendix B Serimux User and Administrator Characteristics UsersRJ45 Signal RJ45 Signal DB-25MAppendix C- Cable Adapters RJ45 Signal DB-25F Index SpecificationsWarranty Information Ethernet Pinouts