NTI SERIMUX SERIES CONSOLE SWITCH
INTERCONNECTION CABLE WIRING METHOD
The cable connecting the terminals and devices to the SERIMUX must be terminated with RJ45 connectors and must be wired according to the EIA/TIA 568 B industry standard. Wiring is as per the table and drawing below.
|
|
|
|
|
|
| Pair 3 |
|
|
| ||
|
|
|
| Pair 2 |
| Pair 1 |
| Pair 4 | ||||
Pin | Wire Color | Pair | Function |
|
| |||||||
|
|
|
|
|
|
|
| |||||
1 | White/Orange | 2 | T |
|
|
|
|
|
|
|
| |
2 | Orange | 2 | R | T | R | T R T | R T R | |||||
3 | White/Green | 3 | T | |||||||||
|
|
|
|
|
|
|
| |||||
4 | Blue | 1 | R | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
5 | White/Blue | 1 | T | + | - | + | - | + | - | + | - | |
6 | Green | 3 | R |
|
|
|
|
|
|
|
| |
7 | White/Brown | 4 | T |
|
|
|
|
|
|
|
| |
8 | Brown | 4 | R |
|
|
|
|
|
|
|
|
Figure 26- View looking into RJ45 female
TROUBLESHOOTING
If the Console Switch is not working properly, consider the suggestions below to see if a solution can be found.
Problem | Cause | |
No Front Panel LEDs are illuminated | No power to SERIMUX | |
SERIMUX is not working properly | • | Poor Connections |
| • Port not configured correctly | |
| • | Ports not initialized |
|
| |
Cannot Connect to port/device | • Port settings not correct | |
| • Wrong cable adapter used | |
| • | Connections are loose |
|
| |
Commands entered from front panel | Buttons are being pressed too rapidly | |
keypad are not accepted |
|
|
|
| |
SERIMUX will not accept username | Usernames and passwords are case | |
or password | sensitive | |
Cannot access user menu on a port | Port is configured as host port | |
I cannot access the View Port Data | Only the ROOT user can access this (see | |
Buffer | page 14) |
Solution
Check all power connections
•Verify that all cables are securely connected
•Verify that the port configuration matches that of the device connected
•
SERIMUX
•Verify proper communication settings (pg 8)
•Verify that adapter is one specified in Appendix C.
•Verify that all cable connections are secure
Try again but slow down the button sequence- approx 1/2 sec between each press.
Verify characters used and enter again.
Configure port as user port. (pg. 10) Login as the ROOT user
If the passwords or other important parameters are not available, the SERIMUX Console Switch can be
Caution: During initialization, the customer modified parameter values will be replaced with the factory default values; all ports will be placed in buffer mode; all passwords will be erased.
If the suggestions above have been tried and the NTI Console Switch is still not functioning properly, a solution to the problem
may be found on our website at http://www.networktechinc.com in our FAQ (Frequently Asked Questions) section, or, please call us directly at (800)
in any way we can.