Network Technologies 8, T15-RS16 operation manual User Controls, User Accessible host list screen

Page 31

NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH

3.2. User Controls

Users can connect only to accessible ports as defined by the administrator. A list of those ports will be displayed with a successful login. Connection can be made using the TERMINAL, or a serial terminal with an emulator (e.g. Windows HyperTerminal) connected to the SERIMUX at an allowed user port

To login, press the [Spacebar] or [Enter] key. Users can login by entering a valid name and password, assigned by the administrator. When prompted for a "User name:", type the administrator assigned user name and press [Enter]. When prompted for the "Password:", type the administrator assigned password and press [Enter].

Note: User names and passwords are case sensitive. It is important to know what characters must be capitalized and what characters must not.

FYI: The administrator may select a user that will automatically login at power up (User 1 is setup by default). In this case, neither name nor password will be required, just press [Spacebar] or [Enter] after power ON the TERMINAL or opening the connected terminal emulator.

After login, the user may connect to an allowed host port, or view host status and parameters. The user is unable to modify port parameters unless the user has been granted administrative privileges.

3.2.1 User "Accessible host list" screen

After successful login, the "Accessible host list" will be displayed. The administrator may choose another initial screen to be displayed, following user's preferences. The Accessible host list includes:

user index number and name

index number and name of the login port

index numbers and names of accessible hosts

Figure 20- A user with limited host port access

From the "Accessible host list", the user can perform the following functions:

Function

Keystroke

Connect to host

[xx] - [Enter] (where xx is the port index number)

Refresh the screen

[Spacebar]

Logout

[Esc] or [Ctrl]+[X] , then [Y] to confirm

FYI: The port index numbers are 2-digit decimal numbers. If the wrong number is entered, simply enter the correct number. Only the last two numbers entered before the [Enter] key is pressed will be accepted. The [Enter] key validates the command; [Esc] or [Spacebar] cancels it.

26

Image 31
Contents RACKMUX-T15-RS16/8 Trademark Table of Contents 1 VT100, VT220 and Console Ansi Command Guide Table of Figures Console Terminal IntroductionConsole Switch Materials Not Supplied, but Required MaterialsFeatures and Functions Rack Mounting Instructions InstallationTerminal vs. Serimux Cable Connections Connect Devices, Hosts, and PowerEthernet cable RJ45 Male Connector Power Up The RackmuxConnect the Serimux and Terminal to a Network Getting Started Setup The TerminalConnect to the Serimux Saving and Exiting SetupF2- Genrl Setup Menu F4- Comm Setup MenuStartup- Accessible host list Password, see Using the Serimux Console Switch1 Login as the administrator Administrator ControlsPort list displays the status of all ports Port ListPort settings menu Port SettingsSetting Description Value Parity Port serial settingsData bit Stop BitDTR line behavior Flow control CommandInter-character delay Xon or Xoff CharactersCopy Port Serial Settings Modem settingsDisplay serial settings for different port number Port data buffer Port data bufferUser List User ListUser settings menu User SettingsCopy User Settings Port access Change administrator password Advanced SettingsLoad new firmware Save current firmware FirmwareSerimux is waiting to save its firmware User Controls User Accessible host list screenUser main menu User main menuPort List screen Limited user accessible Port list¾ Port info User Terse modeTerse mode commands ¾ Connect to port ¾ Accessible host list¾ User Logout Initialize Serimux Console Switch to default settingsFactory reset button ¾ Verbose modeDescription Acceptable Value Default Value Serimux Port CharacteristicsHow To Setup The Terminal Using the TerminalF2- Genrl Setup Menu F1- Disp Setup MenuChanging The Terminal Operating Parameters F4- Comm Setup Menu F3- Keybd Setup MenuPrinter Printer RCV ON/OFF F5- Misc Setup MenuF7- FKeys SET-UP Definition Setup Menu F6-Tabs SET-UP MenuProgrammable Keys F9- Lan Setup MenuF8- Ansbk SET-UP Menu F10- Colr1 Set-up MenuF11- Colr2 Set-up Menu Color Association = OFF/ON Color Setup MenuAttribute = Bold/Blink Palette Display Attribute Foreground Color Background Color Color PalettesColor Palettes Contd Command Enhanced PC Local Keyboard CommandsWyse Terminal Command GuideCommands Supported in Ascii Personalities SameStop parity word Select bell volumeKey/fkey DEL Message CR Sequence DELKey/fkey Sequence Sequence DEL ESC . cursor1Bcolor map ESC a mf attrAttr FcolorLine col ColCcc C Clearing Data 910+/925 Term Editing ContdSending data Pp bb...bb 910+/925 Term Print FunctionsCharacter Sets SetVariable Values for Commands Ldraw FieldFkey KeyScreen Area *e MapDefinition Max Maximum SpeedParity VolumeScroll Scrolling Type Speedlps 1 VT100, VT220 and Console Ansi Command Guide Ansi Command GuideLabel assigned VT100, VT220 Console AnsiCharacter Set Selection ESC Ps finalVT100, VT220 Console Ansi Character Attribute FinalFinal character Character AttributeEditing Functions PsnKc/hc ST String Unshifted function key Console Ansi modeVT100, VT220 Console Ansi Auxiliary Keypad Modes Terminal Status Reports More Terminal Control CommandsTerminal Resets VT100, VT220 Console Ansi Transmission/Printer ControlKeyboard Language 2 VT52 Command GuideVT52 Mode Escape Sequences Command Respond with keyboard language CSI ? 27 Ps nBasic Setup Using Printer Server via Ethernet ConnectionSetup for LPD LPD printing Setup for TftpTftp Printing OSD Main Menu On-Screen Display OSDStandard Controls OSD Control MenuColor Menu Brightness/Contrast MenuPosition Menu OSD Image can be moved to different points on the display Setup MenuKeyboard Layout Keyboard FunctionsKeys of the Number Pad Number PadAttribute Value Hardware Specifications TerminalHardware Specifications Serimux Hardware InformationSerial Port Cabling CPU-to-RACKMUX Ethernet Crossover CableSerial Port Pinouts Cable Adapters RJ45 SignalPin Description Serimux Ethernet PinoutsSUB-D Female connector Terminal Connector Pin Assignments3 4 Dimensional Drawings Index Warranty Information