TABLE 2-1 Filler Panel Replacement Procedures (Continued)
Filler Panel Module | Remove Procedure | Install Procedure | ||
|
|
|
|
|
Storage Drive | 1. | Locate the disk drive filler panel to be | 1. | Locate the vacant disk drive module slot in the |
Module* |
| removed from the server. |
| server, then ensure that the release lever on the |
| 2. | To unlatch the disk drive filler panel, |
| filler panel is fully opened. |
*Hard disk drive |
| press the release lever button then tilt | 2. | Slide the filler panel into the vacant slot by |
or solid state |
| the lever up into the fully opened |
| pressing the middle of the filler panel faceplate |
drive |
| position. |
| with your thumb or finger. |
| 3. | To remove the filler panel from the |
| The release lever will rise as it makes contact |
|
| slot, hold the opened release lever and |
| with the chassis. Do not slide the filler panel in |
|
| gently slide the filler panel toward |
| all the way. Leave the filler panel out |
|
| you. |
| approximately 0.25 to 0.50 inch (6 to 12 mm) |
|
|
|
| from the opening. |
|
|
| 3. | Using your thumb or finger, press on the |
|
|
|
| middle of the filler panel faceplate until the |
|
|
|
| release lever engages with the chassis. |
|
|
| 4. | Close the release lever until it clicks into place |
|
|
|
| and is flush with the front of the server. |
|
|
|
|
|
CPU | 1. | Use an Allen wrench (4mm) to loosen | 1. | Lower the air baffle over the CPU socket, and |
Air Baffle |
| the two mounting screws. |
| align the holes for the mounting screws on the |
(over empty | 2. | Gently pull up the air baffle to expose |
| motherboard. |
CPU socket) |
| the empty CPU socket. | 2. | Insert the two mounting screws, then use an |
|
|
|
| Allen wrench (4mm) to tighten the screws. |
Note – For instructions for adding or replacing chassis component filler panels (for example, network modules or chassis monitoring modules), consult the documentation supplied with your chassis.
Chapter 2 Install Server Module Optional Components | 13 |