Polycom DOC2547A manual Types of Ejector Levers on RMX Components

Page 33

Polycom RMX 2000 Hardware Guide

Types of Ejector Levers on RMX Components

On the RMX, 2 types of ejector levers can be attached to the cards:

An all metal (silver) lever

A modified PMC compatible ejector lever covered by plastic caps with a lock catch

Using the All Metal Ejector Lever

This ejector lever can be moved to 3 positions:

Closed - The ejector levers are fully retracted and pushed up against the card’s panel

Partially Open - For card powering down mode. Partially open the ejector lever(s) until the blue HS LEDs on the card and the Control Unit start flashing. When the HS LED is constantly lit the card is in a powered down mode and you can remove the card.

Warning!

Once the removal sequence is initiated and the HS led flashes, the process cannot be terminated when activated.

Fully Open - The card is released from the MCU housing

Using the Modified PMC Compatible Ejector Lever

This ejector lever can be moved to 3 positions:

Closed/Locked - Ejector lever(s) are gently pushed up against the card’s panel and is locked. Ensure that the lock catch is in the standard closed position (shifted to the right as shown below).

1-27

Image 33
Contents Polycom RMX 2000 System Hardware Guide USA United States Federal Communication Commission FCC Regulatory NoticesChinese Communication Certificate Singapore Certificate Table of Contents Table of Contents Hardware Description Main FeaturesRMX 2000 Specifications Following table summarizes the different system capacities System CapacitiesVideo Resolution Resources with MPM+ Safety Requirements Rack Mount Safety PrecautionsSite Requirements Installation Precautions RMX 2000 Front Panel RMX 2000 ComponentsCntl CPU Component DescriptionComponent Description RTM IP RMX 2000 Rear PanelManagement Network on page G-1 Following items appear on the RMX 2000 rear panelRTM Isdn Cables Connected to the RTM IP & Isdn Cards All external connectors are located on the rear panelRMX 2000 Front Panel LEDs RMX 2000 LEDsFollowing items appear on the RMX 2000 front panel ComponentCard Insertion Initiated If during Card removal Initiated The cardCntl Unit RMX 2000 Rear Panel LEDs Following LEDs appear on the RTM IP cardLED Color Description Name ShMG LEDs Function Name Following LEDs appear on the RTM IsdnPort Type Maximum Possible MPM and MPM+ Configuration ModesCard Resources Bandwidth Type MPM+ Resource CapacitiesHD720p HD1080p @30fps @60fps MPM+ Up toMPM and MPM+ Modes An RMX has two MPM cards installed Both MPM cards are enabledRemove one MPM card Insert one MPM+ card Remove the MPM+ card Insert one MPM card RMX 2000 General Information dialog box opens RMX Chassis TypesComponent Replacement Types of Ejector Levers on RMX Components Fully Open The card is released from the MCU housingHandle Replacing the Cntl ModulePolycom RMX 2000 Hardware Guide Replacing the Power Supply Module Replacing the Fan Drawer Removing the MPM/MPM+ Card from the MCU Replacing a Faulty MPM/MPM+ CardInstalling the Replacement MPM/MPM+ Card Installing a New MPM/MPM+ Card in a Powered On RMXReplacing a RTM Isdn Card PRI Cables Replacing the RTM IP Card