Polycom DOC2547A manual RMX Chassis Types, RMX 2000 General Information dialog box opens

Page 31

Polycom RMX 2000 Hardware Guide

RMX Chassis Types

The RMX chassis can be of type A/B/C or D. The environmentally friendly D-type chassis (indicated by the letter D in the Part Number) is required for use with MPM+ card(s).

The chassis type can be viewed in the Hardware Monitor, by right clicking Slot 0 and then clicking Properties.

The RMX 2000 - General Information dialog box opens.

The RMX Part Number contains the letter A/B/C/D that represents the chassis type, as shown in the capture above.

For more details, see the RMX Administrator’s Guide, Chapter 18, “RMX Hardware Monitoring” .

1-25

Image 31
Contents Polycom RMX 2000 System Hardware Guide USA United States Federal Communication Commission FCC Regulatory NoticesChinese Communication Certificate Singapore Certificate Table of Contents Table of Contents Hardware Description Main FeaturesRMX 2000 Specifications Following table summarizes the different system capacities System CapacitiesVideo Resolution Resources with MPM+ Rack Mount Safety Precautions Safety RequirementsSite Requirements Installation Precautions RMX 2000 Front Panel RMX 2000 ComponentsCntl CPU Component DescriptionComponent Description RTM IP RMX 2000 Rear PanelManagement Network on page G-1 Following items appear on the RMX 2000 rear panelRTM Isdn Cables Connected to the RTM IP & Isdn Cards All external connectors are located on the rear panelComponent RMX 2000 LEDsRMX 2000 Front Panel LEDs Following items appear on the RMX 2000 front panelCard Insertion Initiated If during Card removal Initiated The cardCntl Unit Following LEDs appear on the RTM IP card RMX 2000 Rear Panel LEDsLED Color Description Name ShMG LEDs Function Name Following LEDs appear on the RTM IsdnPort Type Maximum Possible MPM and MPM+ Configuration ModesUp to MPM+ Resource CapacitiesCard Resources Bandwidth Type HD720p HD1080p @30fps @60fps MPM+MPM and MPM+ Modes Both MPM cards are enabled An RMX has two MPM cards installedRemove one MPM card Insert one MPM+ card Remove the MPM+ card Insert one MPM card RMX 2000 General Information dialog box opens RMX Chassis TypesComponent Replacement Types of Ejector Levers on RMX Components Fully Open The card is released from the MCU housingHandle Replacing the Cntl ModulePolycom RMX 2000 Hardware Guide Replacing the Power Supply Module Replacing the Fan Drawer Removing the MPM/MPM+ Card from the MCU Replacing a Faulty MPM/MPM+ CardInstalling the Replacement MPM/MPM+ Card Installing a New MPM/MPM+ Card in a Powered On RMXReplacing a RTM Isdn Card PRI Cables Replacing the RTM IP Card