Kramer Electronics user manual Installing the VP-23RC on a Rack, Before Installing on a Rack

Page 18

Installing the VP-23RC on a Rack

5 Installing the VP-23RC on a Rack

This section describes what to do before installing on a rack and how to rack mount.

Before Installing on a Rack

Before installing on a rack, be sure that the environment is within the recommended range:

 

Operating temperature range

+5°to +45°C (41°to 113°F)

 

Operating humidity range

10 to 90% RHL, non-condensing

 

 

 

 

Storage temperature range

-20°to +70°C (-4°to 158°F)

 

Storage humidity range

5 to 95% RHL, non-condensing

￿ CAUTION!!

When installing on a 19" rack, avoid hazards by taking care that:

1.It is located within the recommended environmental conditions, as the operating ambient temperature of a closed or multi unit rack assembly may exceed the room ambient temperature.

2.Once rack mounted, enough air will still flow around the machine.

3.The machine is placed straight in the correct horizontal position.

4.You do not overload the circuit(s). When connecting the machine to the supply circuit, overloading the circuits might have a detrimental effect on overcurrent protection and supply wiring. Refer to the appropriate nameplate ratings for information. For example, for fuse replacement, see the value printed on the product label.

5.The machine is earthed (grounded) in a reliable way and is connected only to an electricity socket with grounding. Pay particular attention to situations where electricity is supplied indirectly (when the power cord is not plugged directly into the socket in the wall), for example, when using an extension cable or a power strip, and that you use only the power cord that is supplied with the machine.

How to Rack Mount

To rack-mount a machine:

1.Attach both ear brackets to the machine. To do so, remove the screws from each side of the machine (3 on each side), and replace those screws through the ear brackets.

2.Place the ears of the machine against the rack rails, and insert the proper screws (not provided) through each of the four holes in the rack ears.

Note that:

￿In some models, the front panel may feature built-in rack ears

￿Detachable rack ears can be removed for desktop use

￿Always mount the machine in the rack before you attach any cables or connect the machine to the power

￿If you are using a Kramer rack adapter kit (for a machine that is not 19"), see the Rack Adapters user manual for installation instructions (you can download it at: http://www.kramerelectronics.com)

14

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Image 18
Contents Model Contents Figures Tables Atmel Flip WindowIntroduction Getting StartedQuick Start Getting Started Overview About the VP-23RCUnderstanding the Media / Room Controller Section Controlling the VP-23RC Connecting the VP-23RC Rear Panel VP-23RC Configuration ExampleRecommendations for Achieving the Best Performance Term DefinitionYour Presentation Switcher / Controller VP-23RC Front PanelVP-23RC Presentation Switcher / Controller Front View Feature VP-23RC Rear PanelVP-23RC Presentation Switcher / Controller Rear View Feature Function RS-232Reset VS HS VP-23RC Underside PanelHow to Rack Mount Installing the VP-23RC on a RackBefore Installing on a Rack Some models, the front panel may feature built-in rack earsConnecting the VP-23RC Presentation Switcher Section If required, connect a PC to the RS-232 port see Connecting the Balanced/Unbalanced Stereo Audio Input/Output Shielded Twisted Pair STP / Unshielded Twisted Pair UTP Wiring the CAT 5 Line OUT RJ-45 ConnectorWire Color CAT 5 PinoutConnecting to the Media / Room Controller Equipment Connecting the VP-23RC Media/Room Controller Section Setting the Media / Room Controller Program Dipswitches Program Dipswitch SettingsDescription Controlling the VP-23RC Controlling the VP-23RC via a PCConnecting an RS-232 Port to a PC RS-232 Rear Panel Port Location For…Dipswitch Settings Function DescriptionControl Configuration via RS-232 and RS-485 Controlling via the EthernetSelect Properties Internet Protocol TCP/IP Properties Window Operating Your VP-23RC Front Panel ButtonsOperating Your VP-23RC Internet Example of a Typical Setup in the Lecture Auditorium Commands Configuration Button Macro SequenceShows an operating example Presentation Switcher Section Operation Independent Switchers ModeMaster Audio Mode Switching in the Master Audio Mode Presentation Switcher Selector Buttons Macro Sequence Flash Memory Upgrade Flash Memory Upgrade for the Presentation Switcher SectionUpgrading the Firmware Click OK and select ª Load Hexº from the File menu Loading the Hex Atmel -Flip Window Connected Flash Memory Upgrade for the Media / Room Controller Section Installing the Web Applet2 KFR-Programmer WindowTroubleshooting Firmware Upgrade Issues Technical Specifications Includes the technical specifications1Hex Table Audio Gain Control Hex TablesMicrophone Master Out Video Increase Set the Audio Output Gain Control for the Master AudioIncrease or Decrease the Audio Output Gain by One Step DecreaseCommunication Protocol Protocol DefinitionsReset Machine Switch Groups Instruction Codes0111 1000 1001 +23 Limited Warranty 2900-000155 REV