Connecting the VP-23RC Presentation Switcher Section
6.2 Wiring the CAT 5 LINE OUT RJ-45 Connector
Table 5 and Figure 9 define the CAT 5 PINOUT, using a straight
Table 5: CAT 5 PINOUT | Figure 9: CAT 5 PINOUT |
EIA /TIA 568A | ||
|
|
|
PIN |
| Wire Color |
1 | Green / White | |
2 | Green | |
3 | Orange / White | |
4 | Blue | |
5 | Blue / White | |
6 | Orange | |
7 | Brown / White | |
8 | Brown | |
|
|
|
Pair 1 |
| 4 and 5 |
Pair 2 |
| 3 and 6 |
Pair 3 |
| 1 and 2 |
Pair 4 |
| 7 and 8 |
| EIA /TIA 568B | ||
|
|
|
|
PIN |
|
| Wire Color |
1 |
| Orange / White | |
2 |
| Orange | |
3 |
| Green / White | |
4 |
| Blue | |
5 |
| Blue / White | |
6 |
| Green | |
7 |
| Brown / White | |
8 |
| Brown | |
|
|
|
|
Pair 1 |
|
| 4 and 5 |
Pair 2 |
|
| 1 and 2 |
Pair 3 |
|
| 3 and 6 |
Pair 4 |
|
| 7 and 8 |
6.3Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP)
We recommend that you use shielded twisted pair (STP) cable. There are different levels of STP cable available, and we advise you to use the best quality STP cable that you can afford. Our
Although unshielded twisted pair (UTP) cable might be preferred for long range applications, the UTP cable should be installed far away from electric cables, motors and so on, which are prone to create electrical interference. However, since the use of UTP cable might cause inconformity to electromagnetic standards, Kramer does not commit to meeting the standard with UTP cable.
You can connect to a example, the
remote computer graphics acceptor via a receiver (for ), see section 3 .2.
Some Kramer twisted pair products include the Power Connect feature. The
18 | KRAMER: SIMPLE CREATIVE TECHNOLOGY |