Kramer Electronics VP-770 user manual LEVEL1

Page 71

 

1st

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2nd Level

 

3rd Level

 

4th Level

 

Range

 

 

Func

.

Note

 

 

 

Level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group C

None

0 (read only)

293

 

 

 

 

 

 

 

 

 

 

 

 

 

Activate CH1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Activate CH2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bypass

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group D

None

0 (read only)

294

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Activate CH1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Activate CH2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bypass

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Process

Deinterlacing

Method

Line Doubler

0

 

311

 

Volatile parameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

unavailable in

 

 

 

 

 

 

 

 

 

 

Motion Adaptive

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

progressive scan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sync

Current Field

0

 

312

 

Unavailable in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

progressive scan.

 

 

 

 

 

 

 

 

 

 

Older Field

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Film Mode

Off

 

 

0

 

320

 

Unavailable in

 

 

 

 

 

 

 

 

Follow Input

 

 

1

 

 

 

 

progressive scan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24PsF Mode

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diagonal

 

 

 

 

0:3

 

330

 

Unavailable in

 

 

 

 

 

Correction

 

 

 

 

 

 

 

 

 

progressive scan.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unavailable when

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

deinterlacing sync

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is older field

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD Sensitivity

LEVEL1

 

 

0

 

340

 

Unavailable in

 

 

 

 

 

 

 

 

LEVEL2

 

 

1

 

 

 

 

progressive scan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEVEL3

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEVEL4

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEVEL5

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Picture

Brightness

 

 

 

 

-400:400

 

410

 

In the OSD menu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the range appears

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

as -80:80

 

 

 

 

 

Contrast

 

 

 

 

0.1:1.6

 

420

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Color

 

 

 

 

0.1:1.6

 

430

 

 

 

 

 

 

 

 

Color

Blue

 

 

0:4

 

441

 

 

 

 

 

 

 

 

Correction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green

 

 

0:4

 

442

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flesh

 

 

0:4

 

443

 

 

 

 

 

 

 

 

Black Level

 

 

 

 

-80:80

 

450

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gamma

Gamma Off

 

 

0

 

460

 

 

 

 

 

 

 

 

Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gamma 0.4

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gamma 0.8

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gamma 1.2

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gamma 1.6

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gamma 2.0

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gamma 2.4

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gamma 2.8

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dither

Mode0: Disable error diffusion

0

 

470

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode1: In-frame 8:6 conversion

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode2: Intra-frame 8:6 conversion

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode3: In-frame 10:8 conversion

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

66

 

 

 

 

 

 

 

VP-770 - The VP-770 RS-232 Communication Protocol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 71
Contents VP-770 Page Page Contents Figures Introduction Achieving the Best Performance Safety InstructionsGetting Started Recycling Kramer Products Overview VP-770 Overview VP-770 Overview Hdcp Compliance About the Power Connect FeatureUsing Twisted Pair Cable Defining the VP-770 Presentation Switcher/ScalerHdmi Feature FunctionVP-770 VP-770 Overview Installing in a Rack 15-pin HD Connector Pinout Connecting the VP-770VP-770 Connecting the VP-770 Connecting the VP-770 Presentation Switcher/Scaler Wire Color Wiring the TP Line in / Line OUT RJ-45 ConnectorsAudio Input Pinout Microphone PinoutOutput Master Connection OSD MenuOSD Menu Operation Example Level Range FunctionVP-770 The OSD Menu OSD Control Icons Input Menu Setting FunctionVolatile parameter System Window CustomizationChanging the Size of the Window Changing the Size of the Main and/or PiP WindowIncreasing the Width Moving the Position of the Main and/or PiP WindowSelect Window Customization. The following Window appears Resized image does not go beyond the window boundaries Audio Menu Audio MenuSDI Provide a better quality image and a brighter output Process MenuPicture Menu Picture MenuEnhance Menu Enhance MenuScale Menu Applies to the Single Window display mode onlySelecting the Correct Aspect Ratio SettingMaster Connection Settings Miscellaneous Menu Resolution and firmware versionsFollowing message appears on the display Ignore OSD Coloring Luma Keying Feature Emergency Alert System XML File Transfer Text Length Definitions Output ResolutionEAS Requirements Display Modes Single Window Display ModeDual Window Display Mode Activating the Single window ModeRatios of both images are maintained Setting the OSD Menu to PiP Window Control Activating the Dual Window ModeSelecting the PiP Source via the Front Panel Buttons Selecting the PIP SourceSelecting the PiP Source via the OSD Menu Selecting Causes the button to Using the Input Front Panel buttonsControlling the VP-770 Controlling via the Front Panel ButtonsControlling via the VP-770 Web Pages Connecting to the VP-770 via your BrowserControlling via the OSD Menu Connecting the VP-770 via the Ethernet Port Connecting to the VP-770 via RS-232Local Area Connection Properties Window Input Source Ethernet Port Configuration and ControlConnecting the PIP Contact Closure Remote Control PINs Keys Function Controlling via the Infrared Remote Control TransmitterUsing the IR Transmitter Port Tunneling Port TunnelingVP-770 Port Tunneling Flash Memory Upgrade Inputs Technical SpecificationsPC Input Resolutions Default Communication ParametersInput Resolutions Hdmi Input Resolutions DP Input ResolutionsYUV Input Resolutions CV Input ResolutionsTechnical Specifications of the Hdmi Output Signal Output ResolutionsHdmi Output Resolutions PC Output ResolutionsCommunication Protocol Mimicking OSD Using the Communication ProtocolVP-770 RS-232 Communication Protocol Set Command Protocol Table Mimicking OSD Using the Communication Protocol with Legacy ProtocolCharacter Symbols Definitions Meaning SDI 1st 2nd Level 3rd Level 4th Level RangeRGB LevelLEVEL1 Enhance Sharpness 1st 2nd Level 3rd Level 4th Level Range Func 480p60 1st 2nd Level 3rd Level 4th Level Range Func OFF Keystroke Button Code Protocol 3000 Common Operation CommandsOperation commands Protocol Table Mimicking Remote and Front Panel ButtonsPOWER-MODE #CR Network settings commands Identification commandsProtocol Port Page Safety Warning