Delta Electronics SS1-UM-1.05 What to do if you get lost, Starting SunData in the Workabout

Page 15

Warning! If you were already in the Psion System Screen, you’ll see a message Exit System Screen? Press N, so that you stay in the System Screen.

From this point you can launch SunData, the SunScan application, but first it is a good idea to familiarise yourself with the Workabout’s keyboard. The main uses of the keys are explained in the Workabout user Guide on pages 10 and 11.

The following keys are particularly important for the Workabout:

Menu

Pops up a menu of options relevant to your current activity

 

 

 

Move the cursor up and down menu options, or adjust the value of a set-

up parameter

 

 

Cycle through the available settings for a menu option

 

 

 

Enter

Carry out highlighted activity, choose menu option or accept highlighted

setting

 

 

On/Esc

Exit from current activity or menu, abandoning any changes

Tab

 

Gives you and expanded range of choices, especially in file operations

 

 

 

What to do if you get lost

The important thing to remember is that you can get out of any menu by pressing On/Esc, and out of any application by pressing +X. This should get you back to the Psion System Screen, as shown above. If things get really stuck, you may have to reset the Workabout, as explained in its manual on page 20.

Starting SunData in the Workabout

In the System Screen, use the arrow keys to highlight the SunData application, and then press Enter.

SunData will load and then flash up communicating as it tries to connect to the probe. Since you haven’t yet connected the probe, it will let you know that Communications failed, and display this screen (the title screen):

Now, you need to tell SunData to work in Emulator mode.

♦ Press Menu and then use the ← → arrow keys to select the Settings menu, which will look like this:

Use the ↑↓↓ arrow keys to highlight

SunScan Probe, and press Enter to pop

up a dialog box with options on which sensors you have attached.

♦ Use the ← → arrow keys to change the Data from: setting to emulator like this:

Set the Ext sensor to BFS so that a Beam Fraction Sensor will also be emulated.

Press Enter to accept this setting and return to the title screen.

SunScan User Manual v 1.05

SunScan Tutorial 15

Image 15
Contents SS1-UM-1.05 SunScanCE conformity CopyrightAcknowledgements TrademarksContents Technical Reference section Menus and Screens More Psion and file handling notesMeasurement options LAI theoryIndex AppendicesOrganisation of this manual How to use the manualsIntroduction SunScan Canopy Analysis SystemData Collection Terminal Field accessoriesSunScan probe Beam Fraction sensorGetting Started Preliminary checksWorkabout and SunScan probe Checking the Workabout hardware What the s/w does Installing the SunData s/w in your PCInstalling the s/w SunData s/w DisketteRunning SunData Setting up your PCs COM portCommunication checks SunScan probe to PCWorkabout to PC Running SunData in Windows SunScan Tutorial About this tutorialWorking with the Workabout Starting SunData in the Workabout What to do if you get lostStarting the PC software Using a PC instead of the WorkaboutThis page is intentionally blank Working through the menu options Setting up a measurement sessionHot Keys File SavingTaking readings Using the Emulator modeWithout a Beam Fraction Sensor Connecting the SunScan probeConnecting the Beam Fraction Sensor Measuring Leaf Area Index without a Beam Fraction Sensor Averages Reviewing your data fileTransferring the data file to your PC From the WorkaboutTo the PC Initiating the file transfer from the Workabout Meanwhile, on the PC Conclusion of the Tutorial RS232 communication problemsSunData Screens on the Workabout Settings Menus and ScreensFile Utils ContdQuit Navigating the Psion directories and screens More Psion and file handling notesNavigating Psion directories and screens Workabout User GuidePsion subdirectory usage in file select dialogs Re-installing the SunData application icon Deleting unwanted Workabout filesFlashcards reformatting Configuration and data file handling SunData Configuration filesData memory management Data files Default .cfgCreating a configuration file Restoring a configurationDisplaying data files on your PC .PRN file.CSV file Data file layouts and data groups Page Measurement options Experiment designAbove-canopy reference requirements Canopy Sampling volume Canopy type and BFS practicalitiesCanopy type and LAI estimates Planning for the sun’s position Preferred light and weather conditionsAdvice on Absorption and Eladp values Setting EladpAbsorption Estimating Eladp in the field Relationship between Mean Leaf Angle and EladpWorkabout setup SunScan System Measurement modesLAI, PAR and All displays Autolog function Levelling the probe Measurement procedures in the fieldProbe handling in the field Probe GO buttonWorkabout Using the tripodBFS handling in the field Use of the tripodFinding North, and setting the shade ring Levelling the BFSExtension cables, and the location of the BFS Recalibrate option PAR calibrationsFactory light calibration Checking the probe/BFS matchingComparing the calibration with other PAR sensors Routine maintenance and cleaningRestoring the factory calibration Effect of the shade ring on the BFSSunScan probe and Beam Fraction Sensor Environmental and moisture protectionIngredients of the LAI computation method LAI theoryDerivation of Wood’s SunScan canopy analysis equations Major assumptionsTheory versus reality Beers law for canopy absorption Campbells Ellipsoidal LAD equationsTransmission of Diffuse Light Transmission fraction τ Is given by I/I0 Diffuse light transmission cosine corrected sensor Modelling the canopy transmissionDetail Diffuse light hemispherical response sensor Functions used to model canopy transmissionAccuracy of LAI calculations Diffuse light cosine response sensorExp 0.1 . x . atan 0.9 Atan L Q Spher Modelling incomplete PAR absorption and scatteringScientific references Calculating zenith anglesSummary Jones, Hamlyn G Plants and Microclimate second edition. CUP SunScan probe batteries Maintenance and repairTechnical Reference section Checking the batteriesChecking the desiccant Re-setting the factory calibration Checking the PAR calibrationFactory calibration method While running SunData TroubleshootingProblems running the SunData application Psion WorkaboutInsufficient power to write data reported Technical Support Data Collection Terminal type DCT1 Psion Workabout SpecificationsSunScan Probe Type SS1 Beam Fraction Sensor type BF1Logging Cables Carrying Case type SCC1Telescopic Tripod type BFT1 Spares Kit type SPS1Spectral response PAR PerformanceSunScan system cosine response Cosine responses of probe and BFSLogging the probe as a Linear Quantum Sensor AppendicesLogging the Beam Fraction sensor Revision History Upgrading the SunScan systemSunData PC s/w Workabout SunData s/wWorkabout Remote Link File transfer between Workabout and PCChoice of different programs PsiWinSlink and Rcom Example using SlinkDrives on the PC are referred to as REMA, Remc REM = remote Documentation of Rcom and Slink Example using RcomSending a file to a serial printer Using the Workabout Comms applicationAlternative file transfer mechanisms Sending a file to a Communication programGlossary Page Accuracy IndexIndex Field use 39, 46, 48, 50, 51, 58

SS1-UM-1.05 specifications

Delta Electronics has long been recognized for its innovative solutions in power and thermal management technologies. One of its notable products is the SS1-UM-1.05, a compact and efficient power supply module designed to meet the needs of a variety of applications, from industrial automation to telecommunications.

The Delta SS1-UM-1.05 is a key component in the company’s extensive portfolio, providing reliable and stable power supply for both demanding and sensitive electronic equipment. One of the main features of this module is its high efficiency, which typically exceeds 90%. This not only minimizes energy consumption but also reduces heat generation, making it an ideal choice for applications where thermal management is crucial.

Another significant characteristic of the SS1-UM-1.05 is its wide input voltage range, which allows it to operate effectively in various environments. The module supports a voltage range from 90 to 264 VAC, ensuring consistent performance even in fluctuating supply conditions. This versatility makes it well-suited for global applications, accommodating different electrical standards and requirements.

The SS1-UM-1.05 also boasts a compact footprint, which is essential for space-constrained installations. Its design emphasizes not only performance but also ease of integration into existing systems. The module provides multiple output voltage options, allowing it to cater to specific power requirements, whether it be for industrial machinery or consumer electronics.

In terms of technologies, the SS1-UM-1.05 incorporates advanced power conversion technologies that enhance its overall performance. It features overload protection and thermal shutdown mechanisms to safeguard both the module and the equipment it powers from potential damages due to electrical faults. Moreover, it has low electromagnetic interference (EMI) emissions, which is crucial for environments sensitive to electrical noise.

The SS1-UM-1.05 is also designed with a robust enclosure that adheres to stringent safety and environmental standards. This enhances its durability and reliability, ensuring it can withstand harsh operating conditions. With these features, Delta Electronics demonstrates its commitment to delivering high-quality products that meet the evolving needs of industries worldwide.

Overall, the Delta SS1-UM-1.05 power supply module is an exemplary solution for those seeking a reliable, efficient, and compact power source. Its advanced features and technologies make it an indispensable component in modern electronic systems.