BOXLIGHT MP-93i specifications Lamp, Message table, Install the lamp cover and fix it using screws

Page 30

Lamp (continued)

5

Install the lamp cover and fix it using screws.

 

 

• To prevent burn, install the lamp cover and secure it using the screws.

 

 

 

• Do not turn on the power with lamp cover removed.

 

 

 

Lamp cover

 

 

 

 

 

 

 

• Whenever the lamp is replaced, reset the total operation time of the lamp. Do not reset if

 

 

the lamp has not been replaced.

 

 

• Do not perform resetting without changing the lamp, as this can cause lamp breakage.

Screw

2. Reset the lamp time

Please carry out the following operation within 10 minutes from power on, if you replaced the lamp after

2,000 hours.

MAGNIFY VOLUME

OFF

 

POSITION ON

LASER

 

STANDBY/ON

INPUT

3

2

 

 

 

 

MUTE

 

 

1

 

MENU

RESET

RIGHT

 

3

MENU ON

MOUSE ON

1, 2

 

 

 

RESET

BLANK

TIMER

 

 

RGB

VIDEO

 

 

 

 

INPUT

 

 

 

1)Press the RESET button on projector for 3 seconds or remote control TIMER button for 3 seconds and display the total lamp used time.

When accumulated operation time of the lamp reaches 1700 hours, the following display will appear at the bottom of the screen.

2)Press the RESET button on projector or remote control MENU ON button during displaying the lamp used time.

3)Select the “0” on the screen using the MENU ( ) button or DISK PAD.

LAMP 1700 h

LAMP 1700 0 CANCEL

Message table

On-screen display

The following messages are displayed on the screen.

MESSAGE

Action

 

 

CHANGE THE LAMP

Accumulated operation of lamp has exceeded 1,700 hours. It is recommended

AFTER REPLACING LAMP,

to replace lamp. Replace with new lamp. If accumulated operation reaches

RESET THE LAMP TIMER.

2,000 hours, lamp will automatically turn off. *1

CHANGE THE LAMP

Lamp has 1,979 hours on it.

AFTER REPLACING LAMP,

Call a maintenance person. *1

RESET THE LAMP TIMER.

Time is 20 ~ 0. (count down.)

THE POWER WILL TURN

 

OFF AFTER 20 Hr.

 

 

 

Blinking of

When the lamp has 2,000 hours or more on it, the message will blink, and the

CHANGE THE LAMP

power will turns off after 10 minutes.*2

 

 

NO INPUT IS DETECTED

Signal is hot input. (See page 19, 20)

 

 

SYNC IS OUT OF RANGE

The horizontal frequency of the input signal exceeds the range of the projector,

it cannot be displayed. (See page 20, 21)

 

 

 

*1 This message are not displayed after 3 minutes.

But this message are displayed when you turn on the power again.

*2 It is possible to again turn on the power, however the power will go off after about 10 minutes.

30

Image 30
Contents Outline FeaturesContents Operating GuideFor the Customers in U.K Before use Video signal cablesPower cord Instructions to UsersDo not use power supplies other Than that specified Do not look directly at the lens when Lamp is litDo not install this unit in an unstable place If any abnormality occursHandle the power cord carefully Be careful in handling the power cordCleaning Do not step on this unit or do not put a Heavy object on itDo not place this unit where it gets hot When you are not going to use For a long timeClean inside the unit at least once two years VolumeContents of shipping box Names and functions of each partVideo input terminal Remote control sensor Main Power switchAC in socket RGB input terminalRemote control transmitter How to insert batteries Remove the battery compartment coverInstallation Example of the projector and screen installationHow to use foot adjusters Basic operations To project the pictureStandby mode To turn off the powerIndicator lights up orange PLUG&PLAYFreeze Function Magnifying FunctionMemory function Adjustments and functionsTo return to the initial setting On-screen menus are displayed on the screenAdjustment Item Details of adjustment Freeze Magnify SET UPHow to use the SET UP menu Manual OperationDuring AUTO-adjustment AUTO-adjustmentAUTO-adjustment Confirm Screen Adjustment Item Details of adjustmentMenu Image serves of the picture inversion ImageOPT Menu OPT. allows you to control communication function etcConnection to the video signal terminals Connection to the RGB signal terminalExample of computer signal Resolution Standard Display Dots KHz TypeInitial set signals Computer/signal Horizontal Timing µsComputer/signal Vertical Timing lines Serial Control signal terminalPin No RS-232C Mouse PS/2 +5VPS/2 mouse ADB Mac mouseSerial mouse Communication Control command tableControl command table RS232C cable ReferenceControl data table Procedure of default setting the Projector status Procedure of getting the Projector statusProcedure of setting the Projector status Example of command errorAC Inlet Computer Note type Example of system setupConnecting various equipment ComputerDesk typeCleaning the air filter Air filter Filter coverDo not use with removed air filter How to replace lamp Remove the lamp coverLoosen two screws and pull the handle to remove Lamp Lamp Install the lamp cover and fix it using screwsReset the lamp time Message tableIndicator display Blink in the following casesRCA Jack terminal Input terminal Input/Output Dimension diagramAll dimensions shown in inches RCA Jack terminal Terminal