INSTALLATION ADJUSTMENTS
INSTALLATION ADJUSTMENTS
Scheimpfug adjustment
The scheimpfug correction can be adjusted separately for the three tubes within 3 ranges:
range 1 : 1.4 m (55") to 1.9 m (75"), optimum screen width 1.4 m (55")
range 2 : 1.9 m (75") to 3.2 m (126"), optimum screen width 2.4 m (94")
range 3 : 3.2 m (126") to 6 m (236"), optimum screen width 4 m (157")
A correct scheimpfug setting gives the possibility to focus the lenses for a sharp image in all screen areas.
To change the setting from one range to another, some mechanical actions have to done.
range 1 |
|
|
| ||
min. SW : 1.40 m (55") |
|
|
| ||
P |
|
| |||
max. SW : 1.90 m (75") |
|
| |||
|
|
| P |
|
|
range 2 |
|
|
| ||
min. SW : 1.90 m (75") |
|
|
| ||
max. SW : 3.20 m (126") |
|
|
|
| |
| P |
|
| ||
|
|
|
|
|
P
range 3
min. SW : 3.20 m (126")
max. SW : 6.00 m (236")
P
P
| 5975069ABARCOVISION708200498 | |
|