INSTALLATION ADJUSTMENTS
CRT projection angle adjustment
The projection angle of the red and blue CRT's is dependent on the desired size of the projected image. If the centers of green, blue and red do not coincide, the CRT projection angle must be adjusted. Never try to correct this misalignment with the shift correction or the static convergence controls. These controls may only be applied to correct small errors which cannot be corrected by the CRT angle adjustment.
Ensure that the rasters are centered on the CRT face.
Press ENTER to start the CRT angle adjustment procedure. A crosshairs (green and red) will be displayed on the screen.
ENTER continues with the second part
CRT PROJECTION ANGLE
ADJUSTMENT
CRT PROJECTION ANGLE IS THE FIRST STEP OF STATIC CONVERGENCE ADJUSTMENT.
IT IS CRITICAL THAT THE RASTERS ARE CENTERED ON THE CRT FACE PLATES PRIOR TO PERFORMING
THIS STEP.
...
<ENTER> to read more
INSTALLATION ADJUSTMENTS
<EXIT> to return
of the CRT projection angle adjustment. EXIT returns to Raster shift adjustment. ENTER continues to the crosshairs align- ment.
CRT PROJECTION ANGLE
ADJUSTMENT
DURING THIS PROCEDURE,
RED ON GREEN AND THEN
BLUE ON GREEN CROSSHAIRS
WILL BE DISPLAYED
TO ALLOW THE RED AND
BLUE CRTS TO BE ALIGNED
WITH THE GREEN CRT.
LOOSEN BOLTS A AND B
TO PIVOT THE RED CRT,
AND BOLDS C AND D
TO PIVOT THE BLUE CRT.
<ENTER> to continue <EXIT> to return
EXIT returns to raster shift adjustment ADJUST returns to operational mode.
Loosen the four hexagon screws A, A', B and B', upper and lower fixation latch.