11.3 Remote Control Connection & Operation | Chapter 11 |
2.3The configuration of the status code for both normal and alarm operations:
There are total 2 bytes of the status codes. Byte one, the first 8 bits, shows the current status of the operation modes that the unit is in. Byte two, the second 8 bits, shows the current status of the alarm operations of the unit.
BYTE 1
BYTE 2
} | } } | } |
START | STOP START | STOP |
BYTE 1: Status code for normal operation modes |
|
|
|
| ||||
| b7 | b6 | b5 | b4 | b3 | b2 | b1 | b0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LOCK | VCR | SEQU | QUAD | CH4 | CH3 | CH2 | CH1 |
Channel Select
1110 = CH1
1101 = CH2
1011 = CH3
0111 = CH4
Display Mode
0 = Quad screen display
1 = Full Screen display
0 = Auto sequencing mode
1 = Quad or full screen mode
VCR mode
0 = VCR operation
1 = Live operation
Security Lock mode
0 = Security lock ON mode
1 = Security lock OFF mode
Menu Setup mode
00 = Menu setup mode
P.34