2.3The configuration of the status code for both normal and alarm operations:

There are total 2 bytes of the status codes. Byte one, the first 8 bits, shows the current status of the operation modes that the unit is in. Byte two, the second 8 bits, shows the current status of the alarm operations of the unit.

BYTE 1

BYTE 2

}

} }

}

START

STOP START

STOP

BYTE 1: Status code for normal operation modes

 

 

 

 

 

b7

b6

b5

b4

b3

b2

b1

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOCK

VCR

SEQU

QUAD

CH4

CH3

CH2

CH1

Channel Select

1110 = CH1

1101 = CH2

1011 = CH3

0111 = CH4

Display Mode

0 = Quad screen display

1 = Full Screen display

Auto-sequencing mode

0 = Auto sequencing mode

1 = Quad or full screen mode

VCR mode

0 = VCR operation

1 = Live operation

Security Lock mode

0 = Security lock ON mode

1 = Security lock OFF mode

Menu Setup mode

00 = Menu setup mode

P.34

Image 38
Contents Page RP-W119QD Part 2 43 LCD Quad Display RP-817QD, RP-919QD & RP-1020QD Blank Chapter Page Before Installation Combo Cat6 KVM Matrix Cat6 KVMMatrix DB-15 KVM Combo DB-15 KVMPackage Contents Structure Diagram RP-W819QD & RP-W922QD RP-W819QD RP-W922QD Connection RP-W819QD & RP-W922QD RP-W119QD One Man Installation Slides Thumb Screw LCD interchangeable module kitHow to Use the Slides RP-W119QD Connection LCD Specifications RP-W922QD, RP-W819QD & RP-W119QD D x H RP-817QD, RP-919QD & RP-1020QD Structure Diagram RP-817QD, RP-919QD & RP-1020QD Installation RP-817QD, RP-919QD & RP-1020QD Connection RP-817QD, RP-919QD & RP-1020QD RP-117QD, RP-119QD & RP-120QD Structure Diagram RP-117QD, RP-119QD & RP-120QD How to Use the Slides RP-117QD, RP-119QD & RP-120QD Connection LCD Specifications D x H Weight RP117QD seriesFor LCD OSD Menu MembraneOn-screen Menu VCR out Ch1 In, Ch2 In, Ch3 In, and Ch4 In Video in connectorsVCR TerminationsAlarm I/O VCR Connection for Tape Recording Start and Stop ControlSensor Activated Alarm Video Loss AlarmChapter Pin assignment of the male type 9 pin D-sub connector 3 4XX-DF Byte Start Stop Start Channel SelectChapter Quad CH Select Function Button #2 Button #4 Button #5 Setup buttons #1, #2 Function CH Select buttons #5Quad Display Control Quad button #4 Channel Select buttons #5 FunctionDwell Time setup 1 of the Setup Menu Display SettingTitle setup TIME/DATE setupLoss Alarm 2 of the setup menu- Alarm SettingAlarm Hold Duration Save the settings and exit Setup Menu modeStill Frame Display Mode Quad Display ModeFull Screen Display Mode Auto-Sequence ModeVCR Operations Efficiency Input ratingOutput rating Troubleshooting Blank