Appendix: Technical Information
A±1. MP8650 Lamp Replacement (110V machines only)
To replace the lamp on the 3M MP8650 Multimedia Projector, you will need the following:
D2.5 mm hex wrench (shipped with lamp module)
DMetal halide lamp
!WARNING
There are high voltage parts inside the cabinet that could cause an electric shock. Always unplug projector when changing the lamp.
!Caution
Lamp and adjacent metal parts become extremely hot and can cause burns to your fingers. Allow the projector to cool for at least 1 hour before replacing the lamp.
!Caution
Do not touch the inside of the lamp glass with your fingers. Oil from your fingers can contaminate the lamp glass and cause it to crack or burst.
!Caution
Use care when inserting or removing the lamp module from the projector. Excessive force can cause damage to the lamp or projector.
1.Power OFF: Press the Standby/ON button and wait for the fan motor to cycle off. Then, turn off the power switch and UNPLUG THE POWER CORD.
2.Allow projector to cool: If the projector is at operating temperature, wait one hour to allow the metal parts to cool before continuing.
3.Remove Lamp Access Door: Use a 2.5 mm hex wrench to unscrew the lamp cover retaining screws (1) and gently open the cover. Set aside (2).
4.Remove Lamp Module: Slide the old lamp module (4) out of the projector body.
5.Insert Lamp Module: Carefully insert the new lamp module (5) into the opening and slide it all the way back into place. Check the lamp module to be sure that it is fully inserted and flush against the back wall.
6.Secure Lamp Module: Tighten the lamp module retaining screws (6) to secure the lamp in place.
7.Close and Secure Door: Close lamp access door (7) and tighten the retaining screws (8) to secure the door. Turn on projector and test lamp. If lamp light blinks green but lamp does not illuminate, reseat lamp (step 6).