80CONTROLLING THE MULTIPLE PRODUCT
ENGLISH
40.Lamp fault Check (Command: d p) To check lamp fault.
Transmission
[d][p][ ][Set ID][ ][Data][Cr]
* The data is always FF(in Hex).
Acknowledgement
[p][ ][Set ID][ ][OK/NG][Data][x]
*The data is 1 byte long in Hexadecimal. Data
00 : Lamp Fault
01 : Lamp Ok
02 : N/A (DPM/Power Off)
41.Speaker (Command: d v) Turn the speaker on or off.
Transmission
[d][v][ ][Set ID][ ][Data][Cr] Data
00:Off
01:On
Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][x]
42.Sleep Time (Command: f f) Set Sleep Time.
Transmission
[f][f][ ][Set ID][ ][Data][Cr]
Data
00 : Off
01 : 10
02 : 20
03 : 30
04 : 60
05 : 90
06 : 120
07 : 180
08 : 240
Acknowledgement
[f][ ][Set ID][ ][OK/NG][Data][x]
43.Auto Sleep (Command: f g) Set Auto Sleep.
Transmission
[f][g][ ][Set ID][ ][Data][Cr]
Data
00 : Off(Not using the Auto off function)
01 : 15 Minutes(Set turned off when no signal is entered for 15 min.)
Acknowledgement
[g][ ][Set ID][ ][OK/NG][Data][x]
44. Power On Delay (Command: f h)
Set the schedule delay when the power is turned on (Unit: second).
Transmission
[f][h][ ][Set ID][ ][Data][Cr]
Data
00H to 64H (Data value) : 0 to 100 * Refer to 'Real data mapping ’.
Acknowledgement
[h][ ][Set ID][ ][OK/NG][Data][x]